Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
50
SAS 712 U Series User Manual
traffic to flow more efficiently within these logical subgroups. Please consult your network
switch user manual for VLAN setting instructions. Most of the work is done at the switch part.
All you need to do is to make sure that your iSCSI port's VLAN ID matches that of switch port.
If your network environment supports VLAN, you can click
Set VLAN ID
to change the
configurations. Fill in VLAN ID and Priority settings to enable VLAN.
。
VLAN ID:
VLAN ID is a 12-bit number. Its range is from 2 to 4094, while 0, 1, and 4095
are reserved for special purposes.
。
Priority:
The PCP (Priority Code Point) is a 3-bit number and reserved for QoS. The
definition complies with IEEE 802.1p protocol, ranging from 0 to 7, with 0 as the
default value. In normal cases, you don't need to set this value. Using the default will
do just fine.
TIP:
If network ports are assigned with VLAN ID before creating aggregation
takes place, aggregation will remove VLAN ID. You need to repeat the steps to
set VLAN ID for the aggregation group.
Become default gateway:
The default gateway can be changed by clicking
Become default
gateway
. There can be only one default gateway. To remove the default gateway, right click
to bring out the menu and select
Disable default gateway
.
Enable jumbo frame:
The MTU (Maximum Transmission Unit) size can be enabled by
checking
Enable jumbo frame
. Maximum jumbo frame size is
9000
bytes. To disable jumbo
frame, right click to bring out the menu and select
Disable jumbo frame
.
CAUTION:
VLAN ID, jumbo frames for both the switching hub and HBA on host
must be enabled. Otherwise, the LAN connection cannot work properly.
IPv6 support
JetStor unified storage system supports dual-stack IPv4 and IPv6 protocols. Tunneling and NAT
modes are not supported because they are transitional technologies and have performance issues.
Summary of Contents for SAS 712U Series
Page 119: ......