Copyright@1993~2013 Advanced Computer & Network Corp. All Rights Reserved.
91
SAS 712 U Series User Manual
Currently, the system only supports and communicates with Smart-UPS series by APC (American
) and Magatec UPS.
TIP:
Connection with other vendors of UPS can work well, but they have no such
communication features with the system.
First, connect the system to UPS via the included cable for communication. (The cable plugs into
the serial cable that comes with the UPS.) Then set up the shutdown values for when the power
goes out.
This table shows the available options and their descriptions.
Options
Description
UPS Type
Select UPS Type:
None: No UPS or other vendors.
Smart-UPS: APC UPS.
Megatec-UPS: Megatec UPS.
Shutdown battery
level (%)
When below the setting level, the system will shutdown. Setting level to
“0” will disable UPS.
Shutdown delay
(s)
If power failure occurs and system power cannot recover after the time
setting, the system will shutdown. Setting delay to “0” will disable the
function.
Shutdown UPS
Select ON, when power is gone, UPS will shut down by itself after the
system shutdown successfully. After power comes back, UPS will start
working and notify system to boot up. OFF will not.
Status
The status of UPS:
Detecting…
Running
Unable to detect UPS
Communication lost
UPS reboot in progress
UPS shutdown in progress
Batteries failed. Please change them NOW!
Battery level (%)
Current power percentage of battery level.
Summary of Contents for SAS 712U Series
Page 119: ......