System Components Overview
17
11
10GbE iSCSI (RJ45) Port 2
12
12Gb/s Mini SAS HD Port 1
13
12Gb/s Mini SAS HD Port 2
INFORMATION:
Console cable (NULL modem cable) to connect from console port of
the storage system to a RS 232 port on the management PC. The
console settings are on the following: Baud rate: 115,200, 8 data bit,
no parity, 1 stop bit, and no flow control; terminal Type: vt100.
If the
JetStor FX
chassis is configured with a single controller module,
the controller module MUST be installed in the upper slot.
JetStor FX
series supports traditional UPS via a serial port and
network UPS via SNMP. If using the UPS with a serial port, connect
the system to the UPS via the included cable for communication. (The
cable plugs into the serial cable that comes with the UPS.) Then set
up the shutdown values for when the power goes out.
For a greater understanding of the related color and the behavior of the controller module,
please refer to the chapter 5.2,
section in the LED Descriptions chapter.
2.5.
Power Supply Unit
All
JetStor FX
series models are equipped with two redundant and hot swappable PSUs
(Power Supply Units). The PSU for 3U/4U systems and 2U systems are the same, but the
installation direction is different. (If you pull out the PSU from the system chassis, for 4U/3U
system, the sticker on the PSU will be at down side; for 2U system, the sticker will be at right
side).The images and the table below illustrate the location of PSU in the LFF or SFF system.
Summary of Contents for FX Series
Page 108: ...92 Figure 7 1 Download Service Package in the SANOS UI...
Page 112: ...96...