DE LUXE GAS GRATES / INSTALLATION AND OPERATING INSTRUCTION MANUAL
15
When the pilot flame emerges, keep the knob pressed in for a further 8 to 10 seconds to allow
the flame to heat the thermocouple sufficiently which in turn will allow the gas valve to open
and gas to flow to the grate. Release the knob.
In order to light the grate itself, the knob can now be turned in an anti-clockwise direction. The
further the knob is turned, the more gas will flow into the grate.
On no account should the knob be turned to maximum immediately.
Once grate ignition has taken place, the flames may then be adjusted to any level from high /
maximum to low / minimum, by turning the knob clock-wise or anti-clockwise for the desired
result.
Low / minimum flame height with the knob pointing to the small flame icon, on the left hand side
illustration.
High / maximum flame height with the knob pointing to the large flame icon, on the right hand
side illustration.