2.
Enable an Alarm
Using the
„3D button“
, select
„Enabled“
and press to enable the
alarm and display the alarm parameters.
3.
Parameter Values
„Condition“
defines the condition which must be met in order to
trigger the alarm. The value
„X“
will vary with the sensor being used.
4.
File
This item allows you to select the audio file that is played when the
alarm occurs. Press
„F1“
to play the selected audio file. Press
„F2“
to
stop playing the selected audio file.
5.
Activation Switch
If the switch is assigned, the alarm is enabled or disabled according
to the switch status.
6.
Repeat
If the alarm condition occurrence is longer than the selected audio
file, you can use this item to repeat the audio file. If a check mark is
displayed then the audio file will repeat. If an
„x“
is displayed then
the audio file will play only once.
7.
Announce current value by voice
EX Alarms provide the ability to tell you the actual value of a given
sensor’s variable. If you want the alarm value to be announced, then
check this option.
8.
Set Throttle Idle
With this item activated, you model’s throttle will go to idle when the
alarm condition occurrs.
4.
4.
9.4.3 Vario
Located in:
„Menu->Timers/Sensors/Vario
”. There are two types of
acoustic signalling. The first one is controlled directly by the sensor's
alarm. This is mainly useful if a non-EX MVARIO is installed inside the
model. It is possible to assign a switch that enables or disables the
sound. The slider at the bottom shows the actual value of climb/sink
rate.
The second mode of the Vario is dedicated to EX sensors. The
acoustic signalling varies directly depending on the actual
numerical values sent by the sensor. It is also possible to assign a
switch that enables the acoustic signal.
72
Summary of Contents for Duplex DC-16
Page 1: ...computer radio control system DE DC 16 DE FW 1 06...
Page 6: ...computer radio control system DE 5...
Page 7: ...computer radio control system DE 6...
Page 8: ...computer radio control system DE 7...
Page 9: ...computer radio control system DE 8...
Page 10: ...computer radio control system DE 9...
Page 11: ...computer radio control system DE 10...
Page 115: ...computer radio control system DE 114...
Page 116: ...computer radio control system DE 115...
Page 117: ...computer radio control system DE JETI model s r o Lomen 1530 742 58 P bor www jetimodel de...
Page 118: ...computer radio control system EN DC 16 EN FW 1 06...
Page 123: ...computer radio control system EN 5...
Page 221: ...computer radio control system EN 5 5 103...
Page 222: ...computer radio control system EN JETI model s r o Lomen 1530 742 58 P bor www jetimodel com...