Limits Menu, continued
AUX Channel
Function
Remark
AUX-Learn
R/C Active?
Airspeed Control
NOT USED
AUX has no function at all
No
Limiter function
remains active
ON, TrbCtrl ON
AUX switch controls->
- Turbine
(OFF/RUN/AutoOff)
- Airspeed control
Yes Normal
function
ON, TrbCtrl OFF
AUX switch only controls->
- Airspeed control
- Smoker valve (if enabled)
Yes Normal
function
Limits Menu, continued
Value
Explanation
FailSafe delay
Delay before the failsafe function is activated.
Range = 0.1 to 20.0 seconds.
FailSafeTimeOut
Delay before turbine shuts off because of a failsafe.
Range = 0.1 to 20.0 seconds
FailSafeRPM
RPM the turbine will throttle to during a failsafe time out period.
Range = Minimum RPM to Maximum RPM
Drain GasTank
If enabled, after turbine is started and throttled up, the starting gas
valve will open, draining the tank.
Default – Disabled (Off)
Page 50/74