5. Now the ECU can memorize the positions of the throttle and AUX channels. First,
place the throttle stick and throttle trim to low. Next, press
Select Menu
or the LED
I/O board switch, again. This will store the R/C system’s pulse width for immediate
shutdown of the turbine. The green
OK
LED will turn off and the red
Pump running
LED will illuminate. This indicates that the shutdown data has been set correctly.
The GSU display will read:
Æ
Throttle channel “
Idle
” position
Throttle Trim to
maximum:
6. Advance the throttle trim lever to maximum. Press
Select Menu
or the LED I/O
board switch again, to store the R/C system’s pulse width for the turbine idle position.
The red
Pump running
LED will turn off and the yellow
Standby
LED will illuminate.
This indicates that the turbine idle data has been set correctly.
The GSU display will read:
Æ
Throttle channel “
Full Power
” position
Set Throttle to
maximum:
7. Advance the throttle stick to maximum. Press
Select Menu
or the LED I/O board
switch again, to store the R/C system’s pulse width for the turbine full power position.
The yellow
Standby
LED will turn off and the green
OK
LED will illuminate again,
indicating that the turbine full power data has been set correctly. This completes the
learn mode for throttle and initiates the learn mode for the three-position AUX
channel.
The GSU display will now read:
Æ
AUX channel minimum “
Off
” position.
Set AuxChan. to
minimum:
8. Move the AUX channel to the minimum position for
Off
and press
Select Menu
or
the LED I/O board switch again, to store the R/C system’s pulse width for immediate
shutdown of the turbine. The green
OK
LED will turn off and the red
Pump running
LED will illuminate. This indicates that turbine shutdown data has been set correctly.
Page 34/74