The GSU display will read:
Æ
AUX channel middle “
Start/Standby
” position
Set AuxChan. to
center:
9. Set the AUX channel to the middle position for
Start/Standby
and press
Select
Menu
or the LED I/O board switch again, to store the R/C system’s pulse width for
the turbine to start and run. The red
Pump running
LED will turn off and the yellow
Standby
LED will illuminate. This indicates that the turbine start/standby data has
been set correctly.
The GSU display will read:
Æ
AUX channel maximum “
Auto-Off
” position
Set AuxChan. to
maximum:
10. Place the AUX channel on the maximum position for
Auto-Off
and press
Select
Menu
or the LED I/O board switch, to store the R/C system’s pulse width for a normal
shut-off of the engine. The yellow
Standby
LED will turn off and the ECU will now
permanently store the data. This indicates that the “
learn R/C
” procedure is
completed and the ECU now retains the pre-set stick position values. Repeating this
procedure is only necessary when the R/C system is changed or adjusted.