in 1/16th increments or less at a time.
Fence perpendicular to table
The outfeed fence must also be perpendicular to
the table. This can be checked as follows:
8. Place a square against the
casting
(L, Fig.
10) and table.
9. If adjustment is required, adjust
setscrews
N
(Fig. 10).
Alignment is complete when both fence castings
are coplanar (in-line) as shown in Figure 9 and
the outfeed fence is perpendicular to the table.
10. Replace both fences and secure.
Ram Dial Calibration
The cutter guard should be removed or raised to
provide clearance.
Referring to Figure 11:
1. Loosen
the
ram dial
lock knob
(B).
2. Adjust the
outfeed ram dial
(A) fully
clockwise.
3. With
a
straightedge
(F) pressed against both
infeed
and
outfeed fences
(D, E, G) as
reference, both fences should be in-line as
shown and the
scale
(C) should indicate zero.
If step 3 can be successfully achieved, no
calibration is required.
If the fences cannot be brought into alignment (L),
adjust as follows:
4. Remove
fences
(D, E).
5. Using a 10mm wrench, loosen the
lock nut
(O, Fig. 10) that secures the
zero stop set-
screw
(P, Fig, 10) on the
casting
(L, Fig. 10).
6. Loosen or tighten the
setscrew
(P, Fig. 10),
as required, to bring fence castings into
alignment as shown in M.
Note:
Ram Dial Adjust
(A) is fully clockwise
(from step 2).
7. Tighten
lock nut
(O, Fig. 10).
If the
scale
(C) does not indicate zero:
8. Loosen two
screws
(J) that secure the
indicator
(H) and adjust until the zero on the
indicator
(H) is lined up with the zero on the
scale
(K).
9. Tighten
screws
(J).
Repeat steps 2 and 3 to verify that calibration is
Figure 11
13
Summary of Contents for JWS-35X Series
Page 36: ...Table Assembly Drawing 36...
Page 38: ...Fence Assembly Drawing 38...
Page 42: ...Cabinet and Base Assembly Drawing 42...
Page 48: ...Notes 48...