Cutter Guard
Referring to Figure 2:
Mount the
cutter guard
(A) to the
safety guard
holder
(H). Insert two
lock knobs
(B) through the
cutter guard slots and into the
threaded mounting
holes
(J) on the
safety guard holder
(H).
Feather Board
Referring to Figure 2:
Loosen
lock handles
(C) and slide the rail of the
featherboard so the squared edges of the
carriage bolt
(D) engages in the
groove
(F) along
the top of the fence.
Figure 2
Handwheel Handle
Insert the
handle
(A, Fig. 3) into the
handwheel
(B) and secure with a 14 mm wrench.
Electrical connections must
be made by a qualified electrician in
compliance with all relevant codes. This
machine must be properly grounded to help
prevent electrical shock and possible fatal
injury.
General Information
A power plug is not provided with the Model
JWS35X. You may either connect the proper
UL/CSA listed plug or “hardwire” the machine
directly to your electrical panel provided there is a
disconnect near the machine for the operator.
Consult electrical drawings on pages 45-46 for
further clarification of wiring setup.
This machine must be grounded. Grounding
provides a path of least resistance to help divert
current away from the operator in case of
electrical malfunction.
Make sure the voltage of your power supply
matches the specifications on the motor plate of
the machine.
Extension Cords
If an extension cord is necessary, make sure the
cord rating is suitable for the amperage listed on
the machine's motor plate. An undersize cord will
cause a drop in line voltage resulting in loss of
power and overheating.
The chart in
Table 1
shows the correct size cord
to use based on cord length and motor plate amp
rating. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the
cord.
Extension Cord Length *
Amps
25
feet
50
feet
75
feet
100
feet
150
feet
200
feet
<
5
16 16 16 14 12 12
5
to
8 16 16 14 12 10 NR
8 to 12
14
14
12
10
NR
NR
12 to 15
12
12
10
10
NR
NR
15 to 20
10
10
10
NR
NR
NR
21
to
30 10 NR NR NR NR NR
*based on limiting the line voltage drop to 5V at 150% of the
rated amperes.
NR: Not Recommended.
Table 1