5
115 Volt Operation
As received from the factory, your shaper is
ready to run at 115 volt operation. This shaper,
when wired for 115 volt, is intended for use on a
circuit that has an outlet and a plug that looks
the one illustrated in Figure A. A temporary
adapter, which looks like the adapter as
illustrated in Figure B, may be used to connect
this plug to a two-pole receptacle, as shown in
Figure B if a properly grounded outlet is not
available. The temporary adapter should only be
used until a properly grounded outlet can be
installed by a qualified electrician.
This adapter
is not applicable in Canada.
The green
colored rigid ear, lug, or tab, extending from the
adapter, must be connected to a permanent
ground such as a properly grounded outlet box,
as shown in Figure B.
Figure A
Figure B
Important:
In all cases (115 or 230 volts),
make certain the receptacle in question is
properly grounded. If you are not sure, have a
registered electrician check the receptacle.
230 Volt Operation
If 230V, single phase operation is desired, the
following instructions must be followed:
1. Disconnect the machine from the power
source.
2. This shaper is supplied with six motor leads
that are connected for 115V operation, as
shown in Figure C. Reconnect these six
motor leads for 230V operation, as shown
in Figure D.
3. The 115V attachment plug, supplied with
the shaper, must be replaced with a
UL/CSA listed plug suitable for 230V
operation. This plug is illustrated in Fig. E.
Contact your local Authorized JET Service
Center or qualified electrician for proper
procedures to install the plug. The shaper
must comply with all local and national
codes after the 230 volt plug is installed.
4. The shaper with a 230 volt plug should only
be connected to an outlet having the same
configuration as illustrated by the grounded
outlet box in Figure E. No adapter is
available or should be used with the 230
volt plug.
Figure C
Figure D
Figure E
Summary of Contents for JWS-22CS
Page 15: ...15 Table and Fence Breakdown ...
Page 16: ...16 Fence Breakdown ...
Page 20: ...20 Electrical Schematic ...
Page 21: ...21 Electrical Schematic for the Forward Reverse Switch ...
Page 22: ...22 Notes ...
Page 23: ...23 Notes ...
Page 24: ...24 WMH TOOL GROUP INC 2420 Vantage Drive Elgin IL 60124 Ph 800 274 6848 www wmhtoolgroup com ...