Installation and setting up
11
Check that the local AC voltage is appropriate, as indicated on the machine’s
serial number label. If your AC voltage is outside the appropriate range, do not
use the machine. Contact Jem Service for assistance.
S e t t i n g u p
Fill the fluid tank with JEM-approved fluid (see page 19), or connect up the fluid
line extension kit (optional accessory) if remote fluid tanks are being used.
If DMX control is being used, connect the machine to the DMX line (see page
18).
If the Jem Digital Remote is being used (optional accessory), connect the
remote to the Remote socket. (see page 18)
F i n a l c h e c k s
Before applying power to the Roadie Compact, verify the following:
•
the machine is safely located or installed and meets the location
requirements stated on page 10
•
the operator is familiar with, and able to comply with, the requirements
for safe operation listed on page 3
•
the smoke fluid is one of the genuine Jem fluids listed under “Smoke
fluid options” on page 19
•
the machine is electrically grounded (earthed)
•
the AC power distribution circuits and lines are adequately rated for the
current load
T u r n i n g o n t h e p o w e r
Turn on the main power switch located next to the power cable inlet.
Turn on the Standby switch on the control panel.
The display will show
(%!4
for about 8-12 minutes as the machine heats up
to operating temperature and will then change to
1$9
(Ready).
You can then use the control panel to make fog.