Troubleshooting
21
Troubleshooting
Problem
Probable cause(s)
Suggested remedy
Machine not at operating
temperature
Wait 10 to 15 minutes
&/'
set to 0
Increase setting
415.
set to 0
Increase setting
Machine will not produce fog
when control panel or
remote control Fog switch
turned on
DMX signal present
Disconnect or turn off DMX
controller
Fog is only produced from
one output nozzle
One output has heated
faster, the other is not ready
yet
Wait a few more minutes for
the other output to heat
“Flu out” message
displayed, but there is fluid
in the tank
Machine requires priming
Prime machine (page 15)
DMX address setting
incorrect
Change DMX address (page
14)
Machine can be fired from
control panel or remote
control, but not by DMX
controller
Poor connection in DMX line
Check DMX cables and
connections
Smoke output is weak
Machine requires priming
Prime machine (page 15)
Incompatible smoke fluid
Use approved fluid!
Wet, greasy, non-uniform
smoke output, fluid drips or
spits from nozzles, or very
loud noise when firing
machine
Incorrect operating
temperature
Refer to “Setting the
operating temperature” on
page 14
Mains fuse blown
Replace fuse (page 20)
Machine appears dead
No power at AC cable inlet
Check power cable and
circuit breaker