OPERATION
12
‘selection knob’; or the system will confirm the parameter automatically after 3 seconds.
Operation flow as follows:
Step one: ‘Welding mode selection switch’ select TIG 4T or 2T. Press the ‘selection knob’;
Step two: Adjust the
‘
selection knob
’
and select the pre flow time LED (L1 is on); Press the
‘selection knob’ again, the pre flow time LED (L1) and digital scale display are twinkling; It
means the pre flow time can be adjusted.
Step three: If the adjustment is completed, confirm the parameter by pressing the ‘selection
knob’; or the system will confirm the parameter automatically after 3 seconds.
Output pulse selection: Press the ‘selection knob’. Adjust the
‘
selection knob
’
and select the
pulse LED (L11 is on); press the ‘selection knob’ again, the pulse LED (L11) and digital scale
display are twinkling; It means the output pulse function can be turned on or turned off. If the
digital scale display is “ON”, the output pulse function is turned on; if the digital scale display is
“OFF”, the output pulse function is turned off. When the pulse LED (L11) and digital scale
display are twinkling, press the ‘selection knob’ again, the output pulsed conditions transform by
“ON” into “OFF” or transform by “OFF” into “ON”. Operation flow as follows:
Step one: ‘Welding mode selection switch’ select TIG 4T or 2T. Press the ‘selection knob’;
Step two: Adjust the
‘
selection knob
’
and select the output pulse LED (L11 is on); press the
‘selection knob’ again, the pulse LED (L11) and digital scale display are twinkling; It means the
output pulse function can be turned on or turned off.
Select TIG 4T or 2T
Press the ‘selection
knob’
Adjust the ‘selection knob’ and
select the pre flow time LED (L1 is
on); Press the ‘selection knob’
again, the pre flow time LED (L1)
and digital scale display are
twinkling; It means the pre flow
time can be adjusted
If the adjustment is complete,
confirm the parameter by
pressing the ‘selection knob’;
or the system will confirm the
parameter automatically after
3 seconds
Select TIG 4T or 2T
Press the ‘selection knob’