OPERATION
11
are twinkling; It means the welding current can be adjusted. If the adjustment is completed,
confirm the parameter by pressing the ‘selection knob’ or the system will confirm the parameter
automatically after 3 seconds.
Other parameters such as arc force adjustment: press the
‘
selection knob
’
;
Adjust the
‘
selection knob
’
and select the arc force LED(L13 is on); Press the
‘
selection knob
’
again, the arc
force LED(L13) and digital scale display are twinkling; It means the arc force can be adjusted. If
the adjustment is completed, press the
‘
selection knob
’
and confirm the parameter; Or the system
will confirm the parameter automatically after 3 seconds. Operation flow as follows:
Step one: ‘Welding mode selection switch’ selects MMA mode, press the ‘selection knob ’;
Step two: Adjust the
‘
selection knob
’
and select the arc force LED(L13 is on); Press the
‘
selection knob
’
again, the arc force LED(L13) and digital scale display are twinkling; It means
the arc force can be adjusted.
Step three: If the adjustment is completed, press the
‘
selection knob
’
and confirm the
parameter; Or the system will confirm the parameter automatically after 3 seconds.
⒉
TIG parameters adjustment
Adjust ‘welding mode selection switch’ to TIG mode. If in TIG 4T mode and the output pulse
function is turned on, all parameters (L1~L11) of TIG can be adjusted. If in TIG 2T mode and the
output pulse function is turned on, the start current and crater current is 5A; If the pulse function is
closed, the parameter of base current(L5), pulse frequency(L6) and pulse width(L7) can not be
adjusted.
TIG parameters adjustment: The welding current (L4) can be adjusted directly when the
welder is tune on. Adjust the ‘selection knob’, the welding current LED (L4) and the digital scale
display are twinkling; It means the welding current can be adjusted. If the adjustment is
completed, confirm the parameter by pressing the ‘selection knob’ or the system will confirm the
parameter automatically after 3 seconds.
Other parameters adjustment: Take ‘pre flow time’ for an example. Press the ‘selection knob’;
Adjust the
‘
selection knob
’
and select the pre flow time LED (L1 is on); Press the ‘selection knob’
again, the pre flow time LED (L1) and digital scale display are twinkling; It means the pre flow
time can be adjusted. If the adjustment is completed, confirm the parameter by pressing the
Welding mode
selection switch
select MMA
Press the
‘selection
knob’
Adjust the ‘selection knob’ and
select the arc force LED (L13 is
on); Press the ‘selection knob’
again, the arc force LED (L13)
and digital scale display are
twinkling; It means the arc force
value can be adjusted.
If the adjustment is completed,
press the
‘
selection knob
’
and
confirm the parameter; Or the
system will confirm the
parameter automatically after 3
seconds.