OPERATION
13
Step three: Press the ‘selection knob’ again, the output pulsed conditions transform by “ON”
into “OFF” or transform by “OFF” into “ON”.
Complete the adjustment after 3 seconds, the operation panel will return to original condition;
welding current LED (L4) is on. If the welding mode is TIG and the output pulse function is
turned on, the pulse pilot light (L11) is on. If the output pulse function is turned off, the pulse pilot
light (L11) is off. In MMA mode, the pulse pilot light (L11) is off. All preset parameters with hold
function.
Adjust the
‘
selection knob
’
and
select the pulse pilot LED (L11 is
on); Press the ‘selection knob’
again, the pulse pilot LED (L11)
and digital scale display are
twinkling;
It means the output
pulse function can be turned on or
turned off.
Press the
‘selection knob’
again,
the output pulse function
is turned off.