INSTALLATION AND ADJUSTMENT
10
§4 Operation
§4.1 Layout for the front panel and the rear panel
(take TP-1600
for an example)
MMA
GAS
2T HF
4T HF
2T LIFT
4T LIFT
15
14
13
12
11
10
1
2
3
4
5
6
7
8
9
DISPLAY
DC TIG
PULSE
WELDER
HOT
START
ARC
FORCE
SELECTION
f
TP-1600
Welding mode
selection switch
Selection
knob
Ⅰ、
Introduction the pilot light of TP-1600 operation panel
:
⒈
——Pre Flow Time (L1)
⒉
——Start Current (L2)
⒊
——Up Slope Time (L3)
⒋
——Welding Current (Peak Current) (L4)
⒌
——Base Current (L5)
⒍
——Pulse Frequency (L6)
⒎
——
Pulse Width (L7)
⒏
——Down Slope Time (L8)
⒐
——Crater Current (L9)
⒑
——Post Flow Time (L10)
⒒
——Pulse Selection light (L11)
⒓
——Hot Start (L12)
⒔
——Arc Force (L13)
⒕
——Alarm Pilot Light (L14)
⒖
——Power Pilot Light (L15)
Ⅱ、
The function of ‘welding mode selection switch’:
⒈
GAS——Gas test function; In GAS shelf, the gas is given all the time and the welding
is stopped.
⒉
4T_LIFT——TIG Lifting arc, long welding function.
⒊
2T_LIFT——TIG Lifting arc, short welding function.
⒋
4T_HF——TIG HF striking arc, long welding function.
⒌
2T_HF——TIG HF striking arc, short welding function.
⒍
MMA——MMA function.
Ⅲ、
Operations:
1. MMA parameters adjustment
Adjust the ‘welding mode selection switch’ to MMA function. In MMA mode, only three
parameters (welding current, hot start, arc force) can be adjusted.
MMA parameters adjustment: Turn on the welder, the welding current can be adjusted
directly; If adjust the selection knob, the welding current LED (L4) and the digital scale display