JCM Part No. 960-000076R_Rev. 1
© 2007, JCM-American Corporation
4 - 6
Section 4
World Bill Acceptor (WBA®-1x/2x -SS & SS2)
Disassembly/Reassembly
4. Disconnect the harness plug from the Lever
Sensor Board to remove it from the assembly
(See Figure 4-20 c).
Solenoid Lever Assembly Removal
Perform the following steps to remove the WBA
Solenoid Lever Assembly:
1. Pull up on the Latch Release Lever and lift
the entire Solenoid Lever Cover up
(See Figure 4-21 a).
2. Remove the single (1) retaining screw
located at the Cover’s end, and remove the
Transport Cover in the arrow direction
shown in Figure 4-21 b.
Solenoid Lever Sensor Board Removal
Perform the following steps to remove the WBA
Solenoid Lever Sensor Board:
1. Remove the two (2) Solenoid Lever Sensor
Board mounting screws and disconnect the
harness plug from the board to remove it
from the assembly (See Figure 4-22 a & b).
Solenoid Lever Assembly Removal
Perform the following steps to remove the WBA
Transport’s Solenoid Lever Assembly:
1. Remove the spring located at the lower
portion of the Solenoid Lever Assembly
(See Figure 4-23 a).
2. Remove the two (2) Flat Head mounting
screws located on each side of the assembly
(See Figure 4-23 b) and the four (4) retaining
E-rings on the shaft (See Figure 4-23 c).
3. Remove the Solenoid Plunger Return spring
and the two (2) retaining E-rings on the short
plunger shaft located on the previously
removed portion of the Solenoid Lever
Assembly, and remove the shaft (See Figure
4-24 a, b & c).
a)
b)
c)
Figure 4-20
Entrance Lever Sensor Board
Removal
a)
b)
Figure 4-21
Transport Solenoid Cover Removal
a)
b)
a)
Figure 4-22
Transport Solenoid Lever Sensor
Board Removal
a)
b)
c)
b)
c)
Figure 4-23
Transport Solenoid Lever Assembly
Removal