2 INSTALLATION/OPERATION
This section provides installation and operation
instructions for the World Bill Acceptor Series
(WBA). The information within contains the
following features:
•
Installation
•
Lock Installation
•
DIP Switch Configurations
•
Connector Pin Assignments
•
Jumper Configurations
•
Retrieving Bills
•
Clearing a Bill Jam
•
Cleaning/Preventive Maintenance
•
Operational Flowchart
•
Interface Circuit Schematic.
Installation
Perform the following steps to install the WBA
unit:
1. Remove power from host machine.
2. Set WBA DIP Switches if required
(See Figure 2-1). The initial setting is ALL
switches OFF to enable all denominations.
3. Install the WBA into the host machine using
Round Head M4 mounting screws. There are
three (3) mounting holes located on each
side of the frame (See Figure 2-4).
Changing Bill Guides
Unless your WBA had been used with previous
software installed, the correct bill guides should be
installed in the acceptor unit.
Each software package has designated bill guide
types assigned to it (i.e., USA = 66mm width =
Type 1 Bill Guide, EUR5 = 82mm width = Type 5
Bill Guide).
Refer to the software specification for your specific
application to find which bill guide should exist.
To remove the bill guides proceed as follows:
1. First remove the acceptor head from the
main unit, then
2. Push the bill guides out from the back of the
Acceptor Head section with a Flat-blade
Screwdriver (See Figure 2-3).
NOTE: Verify the software in the WBA
before reinstalling it. The DIP Switch
settings are determined by the software.
See the separately provided software
specifications for the DIP Switch settings
for your application.
Figure 2-1
Right Side Panel Dip Switch Block
NOTE: The maximum
length of M4 Round
Head Screws should be
4mm plus the thickness
of the cabinet or
mounting bracket.
Example: If the WBA is mounted on a
bracket that is 2mm thick, the M4 screws
should be no more than 6mm in length.
Figure 2-2