Section 2
UBA Pro RT/RQ™ Series Banknote Recycler
Specifications
© 2019, JAPAN CASH MACHINE CO., LTD.
8
Environmental Specifications
Electrical Specifications
Structural Specifications
Recycler Capacity
***
:
RT Unit: Max. 60 Notes (Max. 30 Notes x 2 Drums)
RQ Unit: Max. 120 Notes (Max. 30 Notes x 4 Drums)
Interfaces:
USB (USB Specification Rev. 2.0 Compliance) (Full Speed/12Mbps)
Photo-Coupler Isolation
RS232C
cc-Talk
*. The Banknotes accepted on the second attempt are included. The Acceptance Rate Test was conducted on more than 100 Banknotes. Refer to the “Software Information
Sheet” for each Country’s Acceptance Rate parameters.
†. Refer to the specific Country’s Barcode Ticket Specification for more details.
‡. Excludes the time lag associated with Host Communication (Power Supply: +24V DC, Temperature: 25º C ±5º C).
**. The average per note when 10 notes are inserted.
††.A key and lock are not included (A tang is provided). Refer to “Cash Box Lock Installation” on page 10 for the installation. (2 Key Hole Caps are fitted in place to cover existing
holes when shipped).
‡‡.The number of Polymer Banknotes stacked depends on the Banknote’s condition and denomination.
***.150mm New Banknote Only
Table 6
RT/RQ Environmental Specifications
Operating Temperature:
5ºC to +50ºC (41ºF to 122ºF) *Depends on hydrothermal conditions
Storage Temperature:
-20ºC to +60ºC (-4ºF to 140ºF) *Depends on hydrothermal conditions
Relative Operating Humidity:
15% to 85% RH (non-condensing)
Relative Storage Humidity:
30% to 85% RH (non-condensing)
Visible Light Sensitivity:
Avoid contact with direct Sunlight
Installation:
Indoors Only
Table 7
RT/RQ Electrical Specifications
*
*. Measured on a new and factory default RQ Unit.
Supply Voltage
†
:
†. Use a Limited Power Source.
24V DC (±5%)
(6A or higher Recommended)
Current Consumption:
Standby: 0.4A
Operation: 2.0A
Peak: 3.8A
Table 8
RT/RQ Structural Specifications
Weight Empty:
RT (with SH2 Box): 8kg (17.63lbs)
RQ (with SH2 Box): 11.4kg (25.13lbs)
Mounting:
Horizontal, 0 degrees, ±0 degrees angle
(Stacking Up (SU) installation is available. Refer to “Installation Procedure” on page 9.)
Outside Dimensions: Refer to “Unit Dimensions” on page 39 of this Service Manual Section.
Table 5
RT/RQ Technical Specifications (Continued)
100
90
80
70
60
50
40
30
20
10
0
0
5
10
15
20
25
30
35
40
45
50
55
60
Hydrothermal Condition Table
Humidity
[%R
H
]
Allowable
and Humidity Range
35ºC/85RH%
50ºC/40RH%
Operating Temperature
15ºC/15RH%
5ºC/40RH%
Temperature [°C]
Summary of Contents for UBA Pro RQ Series
Page 6: ...P N 960 000209R_Rev A 2019 JAPAN CASH MACHINE CO LTD iv THIS PAGE INTENTIONALLY LEFT BLANK...
Page 10: ...P N 960 000209R_Rev A 2019 JAPAN CASH MACHINE CO LTD viii THIS PAGE INTENTIONALLY LEFT BLANK...
Page 57: ...UBA Pro RT RQ Series Banknote Recycler P N 960 000209R_Rev A 2019 JAPAN CASH MACHINE CO LTD...