© 2017 JCM American Corporation
9
March, 2017
Lecture Notes
ENTERING TEST MODE
Diagnostic Tests are initiated using DIP Switch #1.
To enter the Diagnostic Test Mode, proceed as follows:
1. Turn DIP Switch #1 ON
2. Apply power to the Taiko
™
Unit.
The Front Panel LED will flash White.
F
UNCTIONAL
T
ESTS
Table 3 lists the various Taiko
™
Unit Tests and their related DIP Switch
settings.
Table 3
Taiko TEST DIP Switch Settings
Setting Function
SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8
DIP Switch Test
ON
ON
ON
ON
ON
ON
ON
ON
Transport Motor Forward Rotation Test
ON
OFF OFF OFF OFF OFF OFF OFF
Transport Motor Reverse Rotation Test
ON
ON
OFF OFF OFF OFF OFF OFF
Aging Test
ON
ON
OFF
ON
OFF OFF OFF OFF
Solenoid Test
ON
ON
ON
ON
OFF OFF OFF OFF
Acceptance Test
ON
OFF OFF OFF
ON
OFF OFF OFF
Entrance Flapper Test
ON
OFF OFF
ON
ON
OFF OFF OFF
Exit Flapper Test
ON
ON
OFF
ON
ON
OFF OFF OFF
NOTE: DIP Switch #1 is used as the Enable/Disable Switch to
activate or deactivate each of the following Taiko™ Diagnostic Tests.
ON
OFF