© 2017 JCM American Corporation
1 2
March, 2017
Lecture Notes
Test No. 4 - Solenoid Test
To perform Diagnostic Test No. 4, proceed as follows:
1. Set DIP Switches #1, #2, #3 and #4 ON.
2. Set DIP Switch #1 OFF to activate the test.
The following indications will occur:
• The Entrance Flapper will cyclically
turn ON and OFF.
• The Exit Flapper will cyclically turn ON and OFF.
The cycles will repeat until stopped or an error occurs.
• If the Entrance Solenoid fails to energize, the
RED
LED flashes once.
• If the Entrance Solenoid fails to de-energize, the
RED
LED flashes twice.
• If the Exit Solenoid fails to energize, the
RED
LED flashes 3 times.
• If the Exit Solenoid fails to de-energize, the
RED
LED flashes 4 times.
3. Set DIP Switch #1 ON to stop the Solenoid Test.
Test No. 5 - Acceptance Test
To perform Diagnostic Test No. 5, proceed as follows:
1. Set DIP Switches #1 and #5 to ON.
2. Set DIP Switch #1 OFF to start the Acceptance Test.
3. Insert Banknotes.
The following indications will occur:
• The
GREEN
LED will flash a count for the denomination of the Banknote being
accepted. Generally, the lowest legal Banknote value for a specific Country will
cause the
GREEN
LED to count one (1), and increments up for each increasing
denomination Banknote value.
Example:
For US Banknotes, the following
GREEN
Flash counts will
occur:
• 1 flash of the
GREEN
LED = $1
• 2 flashes of the
GREEN
LED = $5
• 3 flashes of the
GREEN
LED = $10
• 4 flashes of the
GREEN
LED = $20
• 5 flashes of the
GREEN
LED = $50
• 6 flashes of the
GREEN
LED = $100
4. Set DIP Switch #1 to ON to stop the Acceptance Test.