© 2017 JCM American Corporation
1 1
March, 2017
Lecture Notes
A
GING
T
EST
E
RROR
C
ODES
If a Sensor error occurs during the Aging Test, the Taiko
™
Unit will stop its
operation. The Sensor causing the error can be determined by counting the
number of Bezel LED flashes and referring to those listed in Table 4.
Table 4
Aging Test Error Codes
Flash No.
and Color
Sensor Location
1
Right Entrance Sensor
2
Left Entrance Sensor
3
Upper Transit Sensor
4
Lower Transit Sensor
5
Entrance Solenoid Sensor
6
Exit Solenoid Sensor
7
VEND Lever Sensor
8
Encoder Sensor
1
Right IR Penetration (Upper to Lower)
2
Left IR Penetration (Upper to Lower)
3
Right Red Penetration (Upper to Lower)
4
Left Red Penetration (Upper to Lower)
5
Right NIR Penetration (Upper to Lower)
6
Left NIR Penetration (Upper to Lower)
7
Right Blue Penetration (Upper to Lower)
8
Left Blue Penetration (Upper to Lower)
1
Right IR Penetration (Lower to Upper)
2
Left IR Penetration (Lower to Upper)
3
Right Red Penetration (Lower to Upper)
4
Left Red Penetration (Lower to Upper)
5
Right NIR Penetration (Lower to Upper)
6
Left NIR Penetration (Lower to Upper)
7
Right Blue Penetration (Lower to Upper)
8
Left Blue Penetration (Lower to Upper)