© 2017 JCM American Corporation
1 4
March, 2017
Lecture Notes
Test No. 6 - Entrance Flapper Test
To perform Diagnostic Test No. 6, proceed as follows:
1. Set DIP Switches #1, #4 and #5 to ON.
2. Set DIP Switch #1 OFF to start the Entrance Flapper Test.
The following indications will occur:
• For normal operation, the
BLUE
LED will flash once each time the Entrance
Flapper Solenoid energizes. A Sensor Error or Solenoid Error is indicated by
alternating
RED
and
BLUE
LED flashes.
3. Set DIP Switch #1 ON to stop the Entrance Flapper Test.
Test No. 7 Exit Flapper Test
To perform Diagnostic Test No. 7, proceed as follows:
1. Set DIP Switches #1, #2, #4 and #5 ON.
2. Set DIP Switch #1 OFF to start the Exit Flapper Test.
The following indications will occur:
• The
BLUE
LED lights each time the Solenoid is energized
• The
RED
and
BLUE
LEDs alternately light if a Sensor or Solenoid Error occurs
• Set DIP Switch #1 ON to stop the Exit Flapper Test.
Sensor Test
A specific test does not exist to test the Taiko
™
Unit’s Sensors.
However, to test the Sensors, activate Test No. 3 - The Aging Test.
All of the Taiko
™
Sensors are tested during this test.
Any Sensor Error will cause a flash code to occur on either the
RED
LED, the
MAGENTA
LED or the
YELLOW
LED.
Refer to the Aging Test Error Codes listed in Table 4 on page 11 to determine
which Sensor failed.