background image

 

2.2.5   Typical Approved Installation of an Offset in Smoke Pipe  

 

 
2.2.6  Installation of Anti-Sway Bracket 

 

 

 

Page 10 
 

Summary of Contents for Tatiana 997CFO

Page 1: ...I de Lh rat 63310 RANDAN FRANCE This appliance is The manufacturer may update this manual from time to time and cannot be responsible for problems injuries or damages arising out of the use or misuse...

Page 2: ...or serious injuries and or important material damages WARNING Do not use materials other than those provided by the manufacturer for use during the installation as they may be safety hazards and their...

Page 3: ...d weather preheat the chimney flue to prevent smoke flow reversal Hold a lighted rolled up newspaper inside the fireplace towards the smoke pipe for a few minutes 6 Only use the grate made by JC Borde...

Page 4: ...ANSI Z 223 1 NFPA 54 2 THE FIREPLACE 2 1 INTRODUCTION The TATIANA 997 CFO fireplace is an energy efficient heat generating fireplace It will provide you with a lifetime of comfort and enjoyment provi...

Page 5: ...e pipe 4 6m to 4 9m 15 to 17 Max 68 8 kg 151 lbs 240 3kg 529 lbs 115 kg 253 lbs 56 5 kg 124 lbs 750mm 29 5 50 3 kg 110 lbs 10m 33 133 5 kg 294 lbs 355 3 kg 782 lbs 115 kg 253 lbs 56 5 kg 124 lbs 4m in...

Page 6: ...ace Warning For centrally located fireplaces a minimum clearance to combustibles of 1 2m 48 must be maintained 360 o around the fireplace For single wall smoke pipe a minimum clearance to combustibles...

Page 7: ...Page 7...

Page 8: ...Page 8...

Page 9: ...Vent Secure Temp ASHT 254mm 10 Ext Dia 305mm 12 Projet Nova Temp TM HT6103 254mm 10 Ext Dia 305mm 12 Dura Tech DTC 254mm 10 Ext Dia 305mm 12 10 chimneys approved to UL 103HT Standard USA installations...

Page 10: ...2 2 5 Typical Approved Installation of an Offset in Smoke Pipe 2 2 6 Installation of Anti Sway Bracket Page 10...

Page 11: ...e to the firescreen Do not overfire this fireplace Max 11kg 24 lbs of firewood as it may overheat causing a hazard permanent damage to the fireplace or in the presence of creosote even igniting a chim...

Page 12: ...allow combustion air to flow under the wood for a more efficient burn This will result in less creosoting greater efficiency and a longer lasting fire 2 3 6 Combustion Air As is common with open firep...

Page 13: ...insulated enclosure around the chimney there might still be draft problems caused by extremely cold weather To correct this it is recommended to preheat the chimney by holding a lit rolled up newspape...

Page 14: ...n soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled 3 Replace the two piece grate and reinstall the firescreen using two cool...

Page 15: ...TS LIST For TATIANA 997 Centrally Located Fireplace Illustration Part Name Part Number Grate for TATIANA 997 Central Model AGF997CFO Expanded Metal Mesh Firescreen PE997FO Combustion Air Intake Recomm...

Page 16: ...claim Returned products are to be shipped prepaid to the distributor for investigation If the product s is are found to be defective Bordelet Industrie S A S will at their option repair or replace suc...

Page 17: ...ginal purchaser This warranty does not cover cost of removal reinstallation or shipping to repair or replace the defective part s nor administration fees incurred by the original purchaser Bordelet In...

Page 18: ...ualified chimney sweep CAUTION Do not install this fireplace vented gas log combination in a confined space or in tightly constructed house without providing for combustion and ventilation air as stat...

Page 19: ...has been applied to joints around windows and door frames between sole plates floors wall ceiling joints wall panels penetrations for plumbing electrical wires gas lines vents and other openings The N...

Page 20: ...ture or other objects around the fireplace that will obstruct the flow of combustion air Maintain a minimum clearance of 1 2m 48 to all objects around the fireplace Keep the room where the fireplace i...

Page 21: ...on fireplace 6 Center gas fire log set on mounting plate making sure that proper clearance will be maintained from the firescreen to prevent damaging it drill mounting holes and bolt screw on gas fir...

Page 22: ...Typical Vented Gas Log Set Page 22...

Page 23: ...he buyer user as a result of injury or damage to an ultimate user or other person caused by the installation of a vented gas log set in a JC Bordelet S A S fireplace whether the injury or damage resul...

Reviews: