Page 3: ...ing 28 USER GUIDE 34 9 SAFETY INSTRUCTIONS FOR THE USER 35 9 1 General safety instructions 35 10 CONTROLLING THE APPLIANCE 37 10 1 Lighting the fire 37 10 2 To light 39 10 3 To extinguish 39 10 4 Remote control version 40 11 CLEANING AND SERVICE INSTRUCTIONS 44 12 DISPOSAL OF PACKAGING AND APPLIANCE 45 UK IRL UK IRL 6 1 INTRODUCTION Note these instructions should be read carefully and retained for...

Page 4: ...as applicable Building Regulations and Standards issued as relevant by the Department of the Environment or the Scottish Development Department UK IRL UK IRL 8 In the Republic of Ireland installation should be carried out in accordance with IS813 ICP3 IS327 Building Regulations Codes of Practice the manufacturer s instructions and any other rules in force Failure to comply with the above could lea...

Page 5: ...ibrelux or similar heatproof board of 12 mm thickness should be placed under it Any under floor vents or openings within the builders opening should be sealed off Do not place the lintel surround or marble stone directly onto the appliance If possible apply a lintel made of cement or something similar UK IRL UK IRL 10 3 1 Builders opening and surround continuing If the builders opening is construc...

Page 6: ...l diameter pipe or liner The inner collar is for connection to a 100 mm internal diameter pipe or liner 2 min 100 max 150 mm factory made insulated flue manufactured to BS 4543 3 max 225 mm x 255 mm conventional brick flue 4 min 100 mm max 175 mm diameter lined brick or stone flue The flue most have a positive up draught The minimum effective height of the flue system must be 3 meter The flue must...

Page 7: ...n the supply to facilitate servicing 4 The connection should be made in 8 mm copper or similar semi flexible tube max 1 meter Ensure that the gas pipe does not interfere with the removal or replacement of the burner tray of the controls 5 The supply gas feed line should enter the appliance through one of the openings in the appliance case Openings are at the back and right side 6 The gas connectio...

Page 8: ... B B B B UK IRL UK IRL 16 4 2 Preparing the appliance continuing 5 Disconnect the TTB cable 6 Remove the burner chamber out of the firebox 4 3 Fitting the firebox 1 Position the firebox in the fireplace opening 2 If the appliance is placed on a combustible floor then a fibrelux or similar heatproof board of 12 mm thickness should be placed under it Any under floor vents or openings within the buil...

Page 9: ...o the flue pipe or chimney liner The flue connector outer collar is for connection to a 125 mm 5 inch internal diameter pipe or liner The inner collar is for connection to a 100 mm internal pipe or liner see fig UK IRL UK IRL 18 4 3 Fitting the firebox continuing 7 Slide the clamping plate with the lip upward under the vent connector The flue connector and pipe or liner rests on the clamping plate...

Page 10: ...x the glass frame UK IRL UK IRL 20 4 4 Placing the log set Never place extra elements of any kind into the combustion chamber To guarantee good combustion the log set may only be installed in the way specified by Faber International Any other arrangement can lead to soot on logs or window Do not use the fire with broken or missing logs The log set consists of a rear log and 3 logs to cover the bur...

Page 11: ...and and Greece Features Manual control will always remain possible The remote control is a radio frequency type and has been approved internationally The remote control generates a unique safety code every time you activate the transmitter it s similar to those used in a car The remote control is easy to install retrospectively UK IRL UK IRL 22 5 2 Installation remote control 1 Connect the transfo...

Page 12: ...functions 6 Check if you can hear a sound and the motor runs when you push a button on the remote control UK IRL UK IRL 24 6 COMMISSIONING functional checks 6 1 Check pilot ignition 1 Push in and turn the control knob A anticlockwise to the setting small flame You will hear a tick meaning there is ignition Hold the knob in and wait for a few seconds while the air is purged 2 Bring the knob back in...

Page 13: ...Flame Supervision Blocked Flue Monitoring System The pilot unit incorporates a system which will shut off the gas supply if the flue is faulty If the flue is faulty the hot flue gasses will pass over and actuate a heat sensitive switch which will shut off the gas supply This monitoring system TTB must not be adjusted bypassed or put out of operation This TTB or any of its parts must only be exchan...

Page 14: ...y out routine servicing at regular intervals It is recommended that the fire is inspected serviced by a competent person at least once a year Important Turn off the gas supply before commencing any servicing Always test for gas soundness after refitting the appliance 8 1 Routine annual servicing 1 Clean if necessary the pilot system the burner the combustion chamber the glass 2 Check the log lay a...

Page 15: ...possible to remove those prints after you burn the appliance for a while they are burnt in 8 1 2 Cleaning the combustion chamber and burner You can clean the combustion chamber with a vacuum cleaner 8 1 3 Propane conversion For coversion from natural gas to propane order for a propane burner unit Please give the serial number from the data badge when you order UK IRL UK IRL 30 8 1 3 Burner tray as...

Page 16: ...3xx 208403XX 2 Glass 04510200 04510200 2 2 Glass ash tray 04510100 04510100 3 Burner NG 20900187 20900187 Burner LPG 20900188 20900188 4 Log set 20793300 20793300 5 HT lead 06017301 06017301 6 Receiver 20604405 20604405 7 Remote control 20603900 20603900 8 Transformer 20900142 20900142 9 Gas control NG 37003089 37003089 Gas control LPG 37003094 37003094 10 Motor Remote control 37003086 37003086 11...

Page 17: ...njector size mm 3x1 2 3x0 8 reduced input restrictor mm 1 6 1 0 Pilot assembly Type SIT 160 SIT 160 code Nr 51 Nr 30 Flue size min 100mm 125mm 100mm 125mm Min Flue height 3 m 3 m Gas control GV36 C5AOEHC68M GV36 C5AODHC68M Remote control adapter 230VAC 50HZ 5VA 230VAC 50HZ 5VA Voltage adapter 4 5 4 5 Batteries remote control 2 x LR03 Alkaline long live 2 x LR03 Alkaline long live Gas connection 8m...

Page 18: ... off the receiver of the remote control if you don t use the fire for a long time Do not let children use the remote control without supervision UK IRL UK IRL 36 Important A suitable Fireguard conforming to BS6539 and BS6778 should be used with this appliance to protect children the elderly or infirm Care should also be taken with pets In your own interest and that of safety all gas appliances mus...

Page 19: ...he first function is to turn on the gas to the pilot this occurs just before reaching the position if the fire has not been lit for some time it may be necessary to hold the knob in this position for some seconds to clear the air from the pipe and allow gas to reach the pilot burner Once gas is available at the pilot continued rotation anti clockwise will cause the piezo igniter to spark This is a...

Page 20: ...er reason you should wait at least 5 minutes before trying to turn it on again Possible causes of pilot extinguish are Operating error Interference of the safety device Failure in the pilot flame system Contact a qualified installer when the appliance goes off regularly 10 4 Remote control version The remote control is only meant to regulate the flames from off till max it functions only when the ...

Page 21: ...control turn knob A to the position 3 To extinguish the pilot turn control knob A to position although it is in order to leave the pilot permanently lit 10 4 3 Setting the right transmission code The receiver has to learn the code from the transmitter which is already done at the factory However the code can disappear if the receiver is disconnected from the mains for a longer period 1 Push the mo...

Page 22: ...lose the cover 5 It might be possible that you have to set the transmission code after changing the batteries see 10 4 3 Note Batteries are chemical waste and should be disposed in accordance with local regulations UK IRL UK IRL 44 11 CLEANING AND SERVICE INSTRUCTIONS Important Turn off the fire and allow it to cool down before commencing cleaning It is recommended that the fire is inspected servi...

Page 23: ...These materials should be disposed responsibly and in conformity with government regulations Batteries are considered chemical waste The batteries should be disposed of responsibly and in conformity with government regulations Remove the batteries before disposing of the remote control Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities ...