background image

W

ARNING

: Never use gasoline or gasoline-type lantern fuel, kerosene, charcoal lighter fluid, waste 

oil or any other combustible liquid to start or rekindle a fire in this fireplace as they may cause an 
explosion or fire which could result in loss of life or serious injuries and/or important material 
damages. They must be stored in sealed metal containers in a well-ventilated room or structure that 
does not adjoin the room where the fireplace is situated.  At all times, keep all other combustible 
materials at least 1.2m (48’’) away from the front and sides of the fireplace.

 

 
WARNING: 

When the fireplace is operating, never reach into it for any reason as this may lead to 

irreversible burns which could lead to serious injuries and/or loss of life. 

 

Caution: Never leave children and babies unattended when there is a fire burning in the fireplace. 
The temperature of the metal surfaces can often exceed 100

 o

 C (212

 o

F) 

which may lead to serious 

burns. 
 
Caution: Never build a wood fire directly on hearth or elevate fire. Always use the grate provided  
with the fireplace to build a fire. Burn only the quantity of fuel it can hold (Max. 11 kg/24 lbs). 

 

Caution: Do not use this fireplace as a fireplace insert or any other product not specified for use 
with this fireplace. 
 
Caution: To operate properly, this fireplace needs combustion air, always make sure that there is a 
sufficient supply of combustion air when operating the fireplace as per ANSI Z 223.1/NFPA 54.

 

2. THE FIREPLACE 
2.1 INTRODUCTION 

The TATIANA 997 CFO fireplace is an energy efficient, heat generating fireplace. It will provide you 
with a lifetime of comfort and enjoyment provided it is installed, maintained and operated properly. 
1- Before beginning the fireplace installation, check the local building codes and, if required,  obtain a 
building permit from the local authorities. Install the fireplace only as described in this manual and 
only using components provided by JC Bordelet S.A.S. 
This fireplace must only serve as a supplementary heat source. A sufficient and permanent heat 
source should already be available in the home. The manufacturer cannot be responsible for 
additional heating costs associated with the use of this supplementary heat source. It is highly 
recommended that the user buy this product from a dealer who can provide installation and 
maintenance advice. 
2-

 

To the installer, please read these instructions carefully and, once the installation is complete, turn 

this manual over to the consumer for future reference. 

2.1.1 Parts Required 

1- The TATIANA 997 centrally-mounted fireplace, required lengths of smoke pipe, a supporting frame 
and a load bearing support to connect and support the fireplace, smoke pipe and chimney. 
2-A High-Temperature insulated 254mm  (10’’) chimney with all the required chimney lengths and 
installation accessories certified to the following standards ULC S-610 (Canadian installations)  &     
UL 103HT (USA installations). 
3-Associated components as per these installation instructions. 

2.1.2 Additional Equipment  

Outdoor Combustion Air Intake (Recommended Option) 
 
 
 
 
 
 
 
 
Page 4 
 

 

Summary of Contents for Tatiana 997CFO

Page 1: ...I de Lh rat 63310 RANDAN FRANCE This appliance is The manufacturer may update this manual from time to time and cannot be responsible for problems injuries or damages arising out of the use or misuse...

Page 2: ...or serious injuries and or important material damages WARNING Do not use materials other than those provided by the manufacturer for use during the installation as they may be safety hazards and their...

Page 3: ...d weather preheat the chimney flue to prevent smoke flow reversal Hold a lighted rolled up newspaper inside the fireplace towards the smoke pipe for a few minutes 6 Only use the grate made by JC Borde...

Page 4: ...ANSI Z 223 1 NFPA 54 2 THE FIREPLACE 2 1 INTRODUCTION The TATIANA 997 CFO fireplace is an energy efficient heat generating fireplace It will provide you with a lifetime of comfort and enjoyment provi...

Page 5: ...e pipe 4 6m to 4 9m 15 to 17 Max 68 8 kg 151 lbs 240 3kg 529 lbs 115 kg 253 lbs 56 5 kg 124 lbs 750mm 29 5 50 3 kg 110 lbs 10m 33 133 5 kg 294 lbs 355 3 kg 782 lbs 115 kg 253 lbs 56 5 kg 124 lbs 4m in...

Page 6: ...ace Warning For centrally located fireplaces a minimum clearance to combustibles of 1 2m 48 must be maintained 360 o around the fireplace For single wall smoke pipe a minimum clearance to combustibles...

Page 7: ...Page 7...

Page 8: ...Page 8...

Page 9: ...Vent Secure Temp ASHT 254mm 10 Ext Dia 305mm 12 Projet Nova Temp TM HT6103 254mm 10 Ext Dia 305mm 12 Dura Tech DTC 254mm 10 Ext Dia 305mm 12 10 chimneys approved to UL 103HT Standard USA installations...

Page 10: ...2 2 5 Typical Approved Installation of an Offset in Smoke Pipe 2 2 6 Installation of Anti Sway Bracket Page 10...

Page 11: ...e to the firescreen Do not overfire this fireplace Max 11kg 24 lbs of firewood as it may overheat causing a hazard permanent damage to the fireplace or in the presence of creosote even igniting a chim...

Page 12: ...allow combustion air to flow under the wood for a more efficient burn This will result in less creosoting greater efficiency and a longer lasting fire 2 3 6 Combustion Air As is common with open firep...

Page 13: ...insulated enclosure around the chimney there might still be draft problems caused by extremely cold weather To correct this it is recommended to preheat the chimney by holding a lit rolled up newspape...

Page 14: ...n soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled 3 Replace the two piece grate and reinstall the firescreen using two cool...

Page 15: ...TS LIST For TATIANA 997 Centrally Located Fireplace Illustration Part Name Part Number Grate for TATIANA 997 Central Model AGF997CFO Expanded Metal Mesh Firescreen PE997FO Combustion Air Intake Recomm...

Page 16: ...claim Returned products are to be shipped prepaid to the distributor for investigation If the product s is are found to be defective Bordelet Industrie S A S will at their option repair or replace suc...

Page 17: ...ginal purchaser This warranty does not cover cost of removal reinstallation or shipping to repair or replace the defective part s nor administration fees incurred by the original purchaser Bordelet In...

Page 18: ...ualified chimney sweep CAUTION Do not install this fireplace vented gas log combination in a confined space or in tightly constructed house without providing for combustion and ventilation air as stat...

Page 19: ...has been applied to joints around windows and door frames between sole plates floors wall ceiling joints wall panels penetrations for plumbing electrical wires gas lines vents and other openings The N...

Page 20: ...ture or other objects around the fireplace that will obstruct the flow of combustion air Maintain a minimum clearance of 1 2m 48 to all objects around the fireplace Keep the room where the fireplace i...

Page 21: ...on fireplace 6 Center gas fire log set on mounting plate making sure that proper clearance will be maintained from the firescreen to prevent damaging it drill mounting holes and bolt screw on gas fir...

Page 22: ...Typical Vented Gas Log Set Page 22...

Page 23: ...he buyer user as a result of injury or damage to an ultimate user or other person caused by the installation of a vented gas log set in a JC Bordelet S A S fireplace whether the injury or damage resul...

Reviews: