background image

BORDELET INDUSTRIE S.A.S. NORTH-AMERICAN WARRANTY LIMITED 
WARRANTY 

The warranty of the manufacturer extends only to the original purchaser and is not transferable. It takes 
effect upon completion of the installation of the fireplace by an authorized qualified installer and a copy of 
the Installation, Operation and Maintenance Manual must be left with the original purchaser at the same 
time. This warranty covers only new products, which have not been altered, modified or repaired since 
leaving the factory. Proof of purchase (original dated invoice), model name and serial number must be 
supplied when making any warranty claim to the 

local Bordelet Industrie S.A.S. distributor. 

This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper 
installation, lack of maintenance, over firing, negligence or accident during transportation, down-
drafts, or venting problems are not covered by this warranty. 

An authorized qualified installer must perform the installation in accordance with the instructions supplied 
with this product and all Local and National building codes. The installer must also verify that the chimney 
used to vent the products of combustion and all it supports and firebreaks meet all codes and standards and 
that the chimney’s base will be mounted on a JC Bordelet Load bearing Support which will also provide 
adequate mounting and support for the fireplace suspended from it. The authorized qualified installer will be 
held solely responsible for any improper installations not in conformance with the ULC-S610 and UL127 
standards and Local and National building codes, the supplied installation, operation and maintenance 
manual and shoddy or negligent workmanship.  

The manufacturer may require that defective products be returned to the 

local Bordelet Industrie S.A.S. 

distributor

 to support the claim. Returned products are to be shipped prepaid to the distributor for 

investigation. If the product(s) is/are found to be defective, 

Bordelet Industrie S.A.S. 

 will, at their option, 

repair or replace such defective product(s). The product(s) will be shipped back to the original purchaser 
freight collect. Repair work done under warranty, executed at the original purchaser’s home by an 
authorized qualified installer requires the prior approval of the 

local Bordelet Industrie S.A.S. distributor

.  

Bordelet Industrie S.A.S. 

and it’s distributor will not be liable for any and all labour and traveling or 

shipping costs associated with the repair, removal, reinstallation of any one of it’s fireplaces or individual 
component nor administration fees incurred by the original purchaser.  

The manufacturer, 

Bordelet Industrie S.A.S.,

 at its discretion, may decide to repair or replace any part or 

unit after inspection and investigation of the defect. Additionally, 

Bordelet Industrie S.A.S. 

may, at its 

discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any 
warranted but defective parts. 

Bordelet Industrie S.A.S. 

shall in no event be responsible for any special, 

indirect, consequential damages of any nature, which are in excess of the original purchase price of the 
product. 

WARRANTY COVERAGE 

Five Years from date of installation: 

All components incorporated in the fireplace at the factory. 

One Year from date of installation: 

Heat deflectors, ash grille, decorative trims and surrounds, the expanded metal mesh firescreen. 

EXCLUSIONS: 


This warranty does not cover any corrosion due to a saline or corrosive environment, distortion, scratches or 
discoloration due to over firing, damages incurred during shipping, nor any damages caused by improper 
assembly or mounting or improper use of the fireplace. Any defect or damage caused by the use of 
unauthorized parts or other than original parts void this warranty. Any service call related to an improper 
installation or use is not covered by this warranty. 

 

 

Page 16 

Summary of Contents for Tatiana 997CFO

Page 1: ...I de Lh rat 63310 RANDAN FRANCE This appliance is The manufacturer may update this manual from time to time and cannot be responsible for problems injuries or damages arising out of the use or misuse...

Page 2: ...or serious injuries and or important material damages WARNING Do not use materials other than those provided by the manufacturer for use during the installation as they may be safety hazards and their...

Page 3: ...d weather preheat the chimney flue to prevent smoke flow reversal Hold a lighted rolled up newspaper inside the fireplace towards the smoke pipe for a few minutes 6 Only use the grate made by JC Borde...

Page 4: ...ANSI Z 223 1 NFPA 54 2 THE FIREPLACE 2 1 INTRODUCTION The TATIANA 997 CFO fireplace is an energy efficient heat generating fireplace It will provide you with a lifetime of comfort and enjoyment provi...

Page 5: ...e pipe 4 6m to 4 9m 15 to 17 Max 68 8 kg 151 lbs 240 3kg 529 lbs 115 kg 253 lbs 56 5 kg 124 lbs 750mm 29 5 50 3 kg 110 lbs 10m 33 133 5 kg 294 lbs 355 3 kg 782 lbs 115 kg 253 lbs 56 5 kg 124 lbs 4m in...

Page 6: ...ace Warning For centrally located fireplaces a minimum clearance to combustibles of 1 2m 48 must be maintained 360 o around the fireplace For single wall smoke pipe a minimum clearance to combustibles...

Page 7: ...Page 7...

Page 8: ...Page 8...

Page 9: ...Vent Secure Temp ASHT 254mm 10 Ext Dia 305mm 12 Projet Nova Temp TM HT6103 254mm 10 Ext Dia 305mm 12 Dura Tech DTC 254mm 10 Ext Dia 305mm 12 10 chimneys approved to UL 103HT Standard USA installations...

Page 10: ...2 2 5 Typical Approved Installation of an Offset in Smoke Pipe 2 2 6 Installation of Anti Sway Bracket Page 10...

Page 11: ...e to the firescreen Do not overfire this fireplace Max 11kg 24 lbs of firewood as it may overheat causing a hazard permanent damage to the fireplace or in the presence of creosote even igniting a chim...

Page 12: ...allow combustion air to flow under the wood for a more efficient burn This will result in less creosoting greater efficiency and a longer lasting fire 2 3 6 Combustion Air As is common with open firep...

Page 13: ...insulated enclosure around the chimney there might still be draft problems caused by extremely cold weather To correct this it is recommended to preheat the chimney by holding a lit rolled up newspape...

Page 14: ...n soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled 3 Replace the two piece grate and reinstall the firescreen using two cool...

Page 15: ...TS LIST For TATIANA 997 Centrally Located Fireplace Illustration Part Name Part Number Grate for TATIANA 997 Central Model AGF997CFO Expanded Metal Mesh Firescreen PE997FO Combustion Air Intake Recomm...

Page 16: ...claim Returned products are to be shipped prepaid to the distributor for investigation If the product s is are found to be defective Bordelet Industrie S A S will at their option repair or replace suc...

Page 17: ...ginal purchaser This warranty does not cover cost of removal reinstallation or shipping to repair or replace the defective part s nor administration fees incurred by the original purchaser Bordelet In...

Page 18: ...ualified chimney sweep CAUTION Do not install this fireplace vented gas log combination in a confined space or in tightly constructed house without providing for combustion and ventilation air as stat...

Page 19: ...has been applied to joints around windows and door frames between sole plates floors wall ceiling joints wall panels penetrations for plumbing electrical wires gas lines vents and other openings The N...

Page 20: ...ture or other objects around the fireplace that will obstruct the flow of combustion air Maintain a minimum clearance of 1 2m 48 to all objects around the fireplace Keep the room where the fireplace i...

Page 21: ...on fireplace 6 Center gas fire log set on mounting plate making sure that proper clearance will be maintained from the firescreen to prevent damaging it drill mounting holes and bolt screw on gas fir...

Page 22: ...Typical Vented Gas Log Set Page 22...

Page 23: ...he buyer user as a result of injury or damage to an ultimate user or other person caused by the installation of a vented gas log set in a JC Bordelet S A S fireplace whether the injury or damage resul...

Reviews: