15
Rigging Manual
5.2 ANGLE SELECTION
Every SRX906LA and SRX910LA has a single angle selection plate on the center rear of the cabinet. These plates are used to select the
cabinet-to-cabinet splay angle. This panel offers 13 unique positions, labeled in degrees.
SRX906LA AND SRX910LA ANGLE OPTIONS:
0.5 °, 1°, 2°, 3°, 4°, 5°, 6°, 7°, 8°, 9°, 10°, 11°,12°
CAUTION: Every quick release pin in an SRX900 Series system must be set in a hole before the array is flown . Do
not suspend an SRX900 Series system if any pins hang free .
When selecting angles on a stack of SRX900 Series cabinets, always start at the top cabinet and work down to the lowest. Angles are
selected while SRX900 Series cabinets are on the carts and resting on the ground. Since the rigging mechanism is not under load when
the system is on the ground, the link bar can be moved freely to the desired position.
To select an angle, remove the angle pin from the 12˚ STORAGE position and extend the link bar upwards. Align the link bar indicator
with the desired angle indicator on the angle selection plate and re-insert the pin into the corresponding angle hole. Lifting the array from
the ground shifts weight to the quick release pins, making angle selections no longer safe or possible.
LINK BAR INDICATOR