Next, the parameters for the operation of the mixing valve of the second heating circuit are set. You can set a
fixed percentage of valve opening or automatic operation. In addition, it is selected whether the desired tem-
perature of the second heating circuit is to be fixed (then it should be entered) or is to be regulated according to
the heating curve. If the mode with three heating circuits is selected, then instead of the regulated pump of the
second circuit, the control output is used for another mixing valve and analogous variables are set for the valve
of the third circuit as for the valve of the second circuit.
After setting the parameters, the floor dehumidification option can be started before the first startup. It consists of
heating for 30 days to a set temperature imposed by the algorithm. Each day the setting is changed. The mode
can also be started from a day other than the first day.
After completing the whole initiation procedure, you
can start the heat pump.