SERVICE MANUAL
– HEAT PUMP
Enabled
: allows the heater to operate in DHW mode.
Hours
: heater run time
Next thr
: Time after which the component should be
replaced/maintained
Reset h.
: switch to reset the counter
Status
: current status of the heater
Manual
: Option to turn the heater on/off manually, or
set automatic mode
Heater modes
:
Legionella
: heating water to remove Legionella in
DHW mode.
Integration
: supporting the compressor in DHW
mode
Substitution
: replacing the compressor in DHW
mode
Integration by alarm
: integration during alarm in
DHW mode
DHW Boost
: intelligent compressor support in DHW
mode
Thresh
: the ambient temperature threshold, below
which the heater in DHW mode can start up
Diff
: after returning to the higher Diff tem-
perature, the heater cannot start up
Delay
: delay for the heater to start
Act. Level
: the ambient temperature threshold,
below which the heater in DHW mode can start in
smart compressor support mode.
Check Time
: the period of time when the tempera-
ture increment is tested
Delta Value
: temperature increment during Check
Time below which the heater will start for Timeout
Timeout
: the time to start the heater if requested
Act
: current return temperature value
Last
: last measured value of return temperature at
the end of Check Time
Status
: the status of the heater activation
Summary of Contents for ZHHS-01-10K-R290-V5-M