SERVICE MANUAL
– HEAT PUMP
Min
: minimum value of the DHW set temperature that
can be set
Max
: maximum value of the DHW set temperature
that can be set
Fixed Req
: the set control value for the circulating
pump expressed as a percentage (if the control type
is Fixed Speed)
Min
: minimum circulating pump control value for
automatic control
Max
: maximum control value for circulating pump for
automatic control
Regulation type
: selection of the operation mode of
the circulation pump in DHW mode:
•
Fixed speed – constant flow speed
•
Cond temp – speed depending on the con-
densation temperature
Alarm source
: selection between whether the alarm
is to operate according to the Setpoint offset or
Temp. level rules.
Setpoint offset
: the difference between the setpoint
temperature and the measured temperature above
which the cold water alarm will occur
Temp. level
: water temperature below which the cold
water alarm will occur
Startup
: the time after the start of the control in which
the fulfillment of the alarm condition does not cause
the alarm to occur
Run
: the time value for which the alarm condition
must be met to trigger the alarm
Enable Mode
: operation mode of the circulation
pump:
OFF – turned off
Sched. ECO – ECO mode linked to the calendar
Sched. ON – operation mode linked to the calendar
ECO – ECO mode
Always ON – always on
Pump state
: - signaling operation of the circulation
pump
ECO ON Time
: time duration of operating in ECO
mode
ECO OFF TIME
: time duration of standby in ECO
mode