Section 8: Plumbing System
137
The Uni-Doc Utility Center
is located in an exterior compartment and allows you to per-
form the following functions:
Power fill the fresh water tank for remote or dry camping
Use the pump to supply water to fixtures from the fresh water tank
Use the pump to siphon fill or sanitize the fresh water tank from a bucket
Connect to city water at the camp site to supply water to RV fixtures
Winterize the plumbing lines and fixtures
Bypass the hot water heater when winterizing to avoid damage to the water heater
Rinse the black tank to help control odors and prevent waste buildup
Connect up to (3) coax lines with SAT, CABLE and AUX
•
SAT input is wired only to the wall plate for the satellite receiver.
•
CABLE input is wired only to the wall faceplate at the main TV. The faceplate
can switch between CABLE & the outside HDTV antenna. (Refer to
Section 11
Antenna System
).
•
AUX input is wired to wall faceplates of any other secondary TVs in the RV (i.e.
bedroom or exterior). This AUX input is designed for use with an outdoor por-
table satellite dish system mounted on a tripod.
Located above the utility center main panel may be a separate red handled valve to operate
the Water Heater Bypass. The valve has 2 positions NORMAL and BYPASS.
The city water connection inlet is located in the Uni-Dock utility center. Use a non-toxic
drinking water hose dedicated only to supplying fresh water. To prevent contamination,
keep the non-toxic drinking water hose from coming into contact with the ground. Install
the city water connection inlet cap when the fresh water connection is not being used.
The fresh water connection should be disconnected (i.e., the non-toxic drinking hose dis-
connected) when the recreation vehicle is unattended for any amount of time. If something
would happen to the water system, this may help limit water damage to a smaller area.
Do not remove the potable water label.
Nautilus - 2 Valve Position and Routing Information:
Green Handle:
Receives water from Sanitize/Winterize inlet
on front panel.
Sideways: Water goes from the inlet to the pump.
Downward: Water goes to the fresh water tank.
Blue Handle
: Receives water from the City Water Connec-
tion inlet on front panel.
Sideways: Water goes to fixtures in the RV (cold).
Downward: Water goes to or from the fresh water tank.
Using the Uni-Doc utility center:
A check valve is located inside the city water connection inlet
on the utility center. NEVER depress the check valve on the
“CITY WATER CONNECTION” inlet with pressure in the
line. It will cause irreparable damage to the valve function and
the inlet will leak water.
Summary of Contents for Eagle FW 2021
Page 2: ......
Page 10: ...8...
Page 24: ...Section 1 Warranty Service 22 Notes...
Page 34: ...Section 2 Occupant Safety 32 Notes...
Page 42: ...Section 3 Pre Travel Information 40 Notes...
Page 66: ...Section 4 Vehicle Operation 64 Notes...
Page 122: ...Section 7 Fuel Propane System 120 Notes...
Page 168: ...Section 9 Heating Cooling 166 Notes...
Page 180: ...Section 10 Appliances 178 Notes...
Page 206: ...Section 14 Travel Camping Storage Checklists 204 Notes...