90
“Alarms” menu, press “Confirm” button to save the parameters.
Step 8: PTZ Linkage
Move “Active Frame” to “PTZ Linkage” button, press
[
ENTER
]
key to enter into “PTZ
Linkage” setup menu:
First select one camera, then select one of following PTZ linkage:
Preset: Set the flag as “
” to enable preset, in the preset number edit box and
input one preset number that has been setup already. Please refer to chapter
5.14 for preset setup.
Sequence: Set the flag as “
” to enable sequence and input one sequence
number that has been setup already. Please refer to chapter 5.14 for sequence
setup.
Tour
: Set the flag as “
” to enable Tour. Please refer to chapter 5.14 for Tour
setup.
Press “Confirm” button to save and return “Alarms” menu. Press “Cancel” button or
[
ESC
]
key to abort and return “Alarms” menu.
Note: Please make sure that the PTZ you are using can support preset, sequence
and Tour functions. Also make sure that you setup them in PTZ menu. One external alarm
input can trigger many cameras PTZ linkage.
Step 9: Copy the parameters to other external alarm input