Relay function
Number of relays
Number of connection
points per relay
Safety
2
2 (1 T contact)
Horn
1
2 (1 T contact)
Control / Movement
9 or 12
2 (1 T contact)
A large label in the housing cover gives the following information to facilitate
configuration and maintenance of the system:
- connection point numbers
- wiring indication
- fuse characteristics
- a table showing the buttons / relays correspondence
4.2.1- Connection to relays
Connections are made on spring terminals with connection points identified by
numbers.
The flexible wire section (without end-fitting) is between 0.08 mm square and 2.5
mm square.
No common line is provided on the printed circuits (all contacts are potential-free).
Summary table of relays available on receiver :
4.2.2- Relay characteristics
- Characteristics of safety relays
The two safety relays are active when the «On/Horn» button is pressed.
These relays are auto-maintained until passive or active stop.
• Contacts : AgNi 90/10
• Maximum power at cosphi=1 : 2000 VA
• Maximum current switching : 8 A
• Maximum voltage switching : 250 VAC
• Minimum current / voltage advised switching : 100 mA / 12 VDC
• 100 000 switching cycles at 250 VAC, 8 A, cosphi=1
• 100 000 switching cycles at 24 VDC, 6 A
• Tests per EN 60947-5-1 :
DC13 at 2 A / 24 VDC
AC15 at 3 A / 250VAC
Summary of Contents for UC 323882G
Page 2: ... 2 UC 323882G ...
Page 50: ...DE 5 0 UC 323882G EN FR ...
Page 98: ...DE 9 8 UC 323882G EN FR ...
Page 146: ...DE 146 UC 323882G EN FR ...
Page 147: ...UC 323882G 147 EN FR DE Annexes Appendix Anhang ...
Page 148: ... 148 UC 323882G EN FR DE ...
Page 163: ...UC 323882G 163 NOTES ...