Configuration
Configuring the Receiver
Configuring the External UHF Modem
62
www.javad.com
• RTK Parameters, Dynamics – select Static or Kinematic.
• RTK Parameters, Ambiguity fixing level – (not applicable to RTK Float) select either Low,
Medium, or High for indicator states of 95%, 99.5%, or 99.9%, respectively. The RTK
engine uses the ambiguity fix indicator when making decisions whether or not to fix
ambiguities. The higher the specified confidence level, the longer the integer ambiguity
search time.
Figure 3-18. Rover Configuration
9. For RTK surveys, click the Ports tab and set the following port parameters for the serial
port (Table 3-6), then click Apply (Figure 3-19 on page 63).
Note:
For post-processed surveys, keep the default values for these parameters.
Table 3-7. Receiver Parameters for the Ports Tab
Parameter
Base Receiver
Rover Receiver
Input
n/a (Leave the default.)
Select the same
differential correction
format selected for the
Base.
Output
Select the type and format of differential corrections.
Select “None”.
Period (sec)
Enter the interval at which the receiver will transmit
differential corrections.
n/a (Leave the default.)