Jason International, Inc. •
501.771.4477
Page 13 of 24
Customer Service : 800.255.5766
Copyright © 2013 Jason International.
CONTROL BOX CONNECTIONS (cont.)
SIGNATURE EDITION AIRMASSEUR
®
Jason’s Signature Edition AirMasseur
®
system is the most
advanced bath manufactured by Jason International, Inc.
and features the ultimate in luxury bathing for the leisure
bath industry. The blower control box must be properly
connected for the bath to function correctly.
THE BLOWER CONTROL BOX
The blower, keypad, LED light, ozone sanitation unit, and
water level/temperature sensor must be plugged into the
proper receptacle for correct operation of the AirMasseur
®
system. See Figure 17 for connections:
(A) The junction box for the blower control box must be
connected into a 240v, 15 amp GFCI dedicated circuit.
(B) Pre-wired power cord to blower (C).
(D) 6-pin mini-DIN terminal for the water/temperature sensor
(E) 6-pin mini-DIN terminal for the LED light.
(F) 8-pin mini-DIN terminal for installation of AirMasseur
®
keypad
(G) Pre-wired power cord to ozone unit.
Figure 17
NOTE: This diagram (Figure 17) also applies to 50 Hz,
240v controls, and power supply systems.
MICROSILK® CONTROL BOX CONNECTIONS
STANDARD EDITION MICROSILK
®
Jason’s Standard Edition MicroSilk
®
system features the
best in luxury bathing for the leisure bath industry. To as-
sure that your bath functions properly, the MicroSilk
®
pump
control box must be properly connected.
NOTE: For 120v systems, the power cord for the Mi-
croSilk
®
control box must be plugged into a 120v, 20
amp GFCI dedicated circuit.
THE MICROSILK
®
CONTROL BOX
The MicroSilk
®
unit and Keypad must be plugged into the
proper receptacles for correct operation of the MicroSilk
®
system. See Figure 18 for connections:
(A) The power cord for the MicroSilk
®
control box must be
connected into the proper GFCI dedicated circuit for the
system (see note above).
(B) Pre-wired power cord from MicroSilk pump to control (C).
(D) Eight-pin mini-DIN terminal for the MicroSilk
®
Keypad.
(E) Six-pin mini-DIN terminal for optional LED light.
Figure 18
NOTE: This diagram (Figure 18) also applies to 50 Hz,
240v pumps, controls, and power supply systems. Except
that the MicroSilk
®
Pump junction box must be connected
into one dedicated 240v, 20 Amp GFCI circuit.