EVOLVE200 PLUS USER MANUAL
28
- in the right side, the display shows the advance setting
parameters and function effect on the welding wave.
2.7.6 TIG GLICK FUNCTION
The Glick function is available in TIG 4T mode.
By this function, it is possible to change the set of output
current during the welding.
The set will be reduced in % as the GLICK setting: setting
range OFF-90.
.
The GLICK setting is available in the advanced setting menu.
By the knob can be select the set.
Example: If the GLICK setting is 50, and the output current set is 130A, the reduction of set will be at 75A.
The output current set will be changed by a short pressing of the TIG torch switch.
By the short pressing of the torch switch, you can reduce the set, and/or return back to the machine setting
output current.
By a long pressing, the welding will be stopped.
To disable GLICK function, you set it in OFF.