13
TECHNICAL SPECIFICATIONS
* When using the EP
-
45SC via a portable transformer, please ensure that you use a suitably sized 115v
transformer or the add
-
on compressor start up performance will be impacted.
Please Note
Due to variations in manufactured products all claimed performance ratings, capacities, measurements,
dimensions and weights quoted are approximate only. Achievable performance and ratings when in use
can depend upon correct installation, applications and use along with regular maintenance and service.
Parameter
Unit
Jasic Arc EP
-
45 PFC
Jasic Arc EP
-
45SC PFC
Rated input (U1)
V & Hz
AC 95 ~ 265V 50/60
AC 95 ~ 265V 50/60
Rated input current (Ieff)
A
115V
-
20
230V
-
11.5
115V
-
26
230V
-
15
Rated input current (Imax)
A
115V
-
31
230V
-
23
115V
-
37
230V
-
27
Rated input power
kVA
115V
-
3.6
230V
-
5.3
115V
-
10 *
230V
-
6.2
Cutting current range
A
115V
-
20 ~ 30
230V
-
20 ~ 45
115V
-
20 ~ 30
230V
-
20 ~ 45
Rated operating voltage
V
115V
-
92
230V
-
98
115V
-
92
230V
-
98
Rated duty cycle (X)
(rated at 40°C)
%
30A @ 25%
45A @ 25%
Clean cut
mm
115V
-
6
230V
-
15
115V
-
5
230V
-
12
Severance cut
mm
115V
-
12
230V
-
22
115V
-
10
230V
-
20
Pierce cut
mm
115V
-
4
230V
-
12
115V
-
3
230V
-
10
No load voltage (OCV) (U
0
)
V
300
300
Plasma Torch
-
IPT60 (6m)
IPT60 (6m)
Pilot Arc start mode
V
Non HF
Non HF
Efficiency
%
86
86
Idle state power
W
< 50
< 50
Power factor
cos
φ
0.99
0.99
Standard
-
EN60974
-
1
EN60974
-
1
Protection class
IP
IP23S
IP23S
Insulation class
-
H
H
Noise
Db
< 110
< 110
Operating temperature range
°C
-
10 ~ +40
-
10 ~ +40
Storage temperature
°C
-
25 ~ +55
-
25 ~ +55
Size (with handle)
mm
546 x 166 x 341
547 x 187 x 558
Net weight
Kg
10
26.6
Overall weight
Kg
14.5
33.6
Summary of Contents for EVO 2.0 EP-45