27
USER SET UP
Before starting any welding activity ensure that you have suitable eye protection and
protective clothing. Also take the necessary steps to protect any personnel within the
welding area.
Output connections
Plasma torch
The IPT60 plasma torch supplied with
your Jasic plasma machine has the
‘
euro style
’
power/gas connection (in this case the gas used is
compressed air), pilot cable and the torch switch pin
connections.
The Jasic plasma cutting systems and torches incorporate a safety circuit to prevent
operator injury when changing consumables etc. This is a simple circuit that breaks the
electrical torch switching as soon as the retaining cap is removed
preventing machine operation. Without such protection
circuitry, as previously mentioned, the open circuit voltage
could be as high as 350V DC at the torch head
The torch head encompasses a full set of consumables as
shown right, these consumables are made up of a cooling
tube, torch electrode, swirl ring for gas distribution, cutting
tip, retaining cap and if required a stand off device to ensure
the same distance between tip and material being cut.
Fitting the supplied plasma torch
On the Jasic EVO range of plasma machines, the plasma torch fitting instructions (shown below) need
to be observed.
Locate plasma torch plug into euro connector socket as shown in image 1
Push the torch as shown in image 2 and then rotate the locking nut clockwise until fully connected
and tight as shown in image 3
Image 1
Image 2
Image 3