background image

 

SAFETY INSTRUCTION 

 

These general safety norms cover both arc welding machines and plasma cutting machines unless            
otherwise noted. 
It is important that users of this equipment protect yourselves and others from harm or even death. 
The equipment must only be used for the purpose it was designed for. Using it in any other way could    
result in damage or injury and in breach of the safety rules. 
Only suitably trained and competent persons should use the equipment.  
Pacemaker wearers should consult your doctor prior to using this equipment. 
PPE and workplace safety equipment must be compatible for the application of work involved. 

 

Always carry out a risk assessment before carrying out any welding or cutting activity 

 

General electrical safety 

 

The equipment should be installed by a qualified person and in accordance with current 
standards in accordance with current standards in operation. It is the users responsibility    
to ensure that the equipment is connected to a suitable power supply. Consult with your 
utility supplier if required. Do not use the equipment with the covers removed.  
Do not touch live electrical parts or parts which are electrically charged.  
Turn off all equipment when not in use.  

In the case of abnormal behaviour of the equipment, the equipment should be checked by a suitably  
qualified service engineer.  
If earth bonding of the work piece is required, bond it directly with a separate cable with a current        
carrying capacity capable of carrying the maximum capacity of the machine current.  
Cables (both primary supply and welding) should be regularly checked for damage and overheating.  
Never use worn, damaged, under sized or poorly jointed cables.  
Insulate yourself from work and earth using dry insulating mats or covers big enough to prevent any   
physical contact.  
Never touch the electrode if you are in contact with the work piece return.  
Do not wrap cables over your body.  
Ensure that you take additional safety precautions when you are welding in electrically hazardous        
conditions such as damp environments, wearing wet clothing and metal structures.  
Try to avoid welding in cramped or restricted positions.  
Ensure that the equipment is well maintained. Repair or replace damaged or defective parts immediately.  
Carry out any regular maintenance in accordance with the manufacturers instructions. 
The EMC classification of this product is class A in accordance with electromagnetic compatibility       
standards CISPR 11 and IEC 60974-10 and therefore the product is designed to be used in industrial       
environment only.  

WARNING: 

This class A equipment is not intended for use in residential locations where the electrical 

power is provided by a public low-voltage supply system. In those locations it may be difficult to ensure 
the electromagnetic compatibility due to conducted and radiated disturbances.  
 

General operating safety  

 

Never carry the equipment or suspend it by the carrying strap or handles during welding.  
Never pull or lift the machine by the welding torch or other cables. Always use the correct lift points or 
handles. Always use the transport under gear as recommended by the manufacturer.  
Never lift a machine with the gas cylinder mounted on it.  
If the operating environment is classified as dangerous, only use S-marked welding equipment with a safe 
idle voltage level. Such environments may be for example: humid, hot or restricted accessibility spaces. 

  

Summary of Contents for Cut 160

Page 1: ...Operator Manual Plasma Cut Series Plasma Cut 160 JP 160 ...

Page 2: ...anty purposes and to ensure you get the correct information should you require assistance or spare parts Date purchased ________________________________________ From where ________________________________________ Serial number ________________________________________ The serial number is normally located on the top or underside of the machine and will begin with AA For further information on your ...

Page 3: ...F declaration 8 LF declaration 8 Materials and their disposal 8 Product Overview 9 Product details and application 9 Technical Specifications 10 Description of Controls 11 Installation 12 What is Plasma 14 Operation 15 Cut Quality 17 Typical Cutting Speeds 18 General Cutting Information 19 Plasma Torch Consumable Spare Parts Lists 20 Maintenance 25 Troubleshooting 26 Plasma Cutting Problems 27 EC ...

Page 4: ...e and overheating Never use worn damaged under sized or poorly jointed cables Insulate yourself from work and earth using dry insulating mats or covers big enough to prevent any physical contact Never touch the electrode if you are in contact with the work piece return Do not wrap cables over your body Ensure that you take additional safety precautions when you are welding in electrically hazardou...

Page 5: ...ulty welding helmets Always ensure there are adequate protective screens or barriers to protect others from flash glare and sparks from the welding area Ensure that there are adequate warnings that welding or cutting is taking place Wear suitable protective flame resistant clothing gloves and footwear Check and be sure the area is safe and clear of inflammable material before carrying out any weld...

Page 6: ...the the welding fume Ensure the welding zone is well ventilated and provision should be made for suitable local fume extraction system to be in place If ventilation is poor wear an approved airfed welding helmet or respirator Read and understand the Material Safety Data Sheets MSDS s and the manufacturer s instructions for metals consumable coatings cleaners and de greasers Do not weld in location...

Page 7: ...eated by high currents may affect the operation of pacemakers or electronically controlled medical equipment Wearers of vital electronic equipment should consult their physician before beginning any arc welding cutting gouging or spot welding operations Do not go near welding equipment with any sensitive electronic equipment as the magnetic fields may cause damage Keep the torch cable and work ret...

Page 8: ...ry current from the power supply network high power systems affect the quality of power provided by the network Consequently connection restrictions or maximum impedance requirements permitted by the network at the public network connection point must be applied to these systems In this case the installer or the user is responsible for ensuring the equipment can be connected consulting the electri...

Page 9: ...ting torch Excellent dynamic characteristics high arc stiffness smooth cutting surface and high cutting performance Current upslope function is available when arc is ignited to carry out cutting which can reduce the arc ignition impact The Cut 160 cutting current can be accurately preset with seamless adjustment which is achieved through the preset current function Thus the machine can be used to ...

Page 10: ... Jasic Cut 160 Rated input voltage V 3PH 400V AC 15 50 60HZ Rated input power kVA 29 2 Rated input current Imax A 62 Rated input current Ieff A 48 Cutting current range A 30 160 Rated output voltage V 144 Rated duty cycle 160A 60 40 C Clean cut mm 45 Severance cut mm 50 Pierce cut mm 26 Minimum air pressure 5 Bar 73psi Minimum gas flow 7 1CFM 220 Ltr min Efficiency 85 Power factor cosφ 0 99 Plasma...

Page 11: ...ng in 4T mode you can remove your finger off the torch trigger and the arc will remain on until you either press the torch trigger again or you remove the plasma arc away from the material being cut 6 Torch connector the plasma torch connection see page 13 for fitting instructions 7 Pressure gauge Used in conjunction with the pressure adjustor this gauge allows you to accurately set the required a...

Page 12: ...d on the front panel of the Cut 160 The inlet air connection is mounted on the rear panel of the machine only connect a suitable dry compressed air supply max 8 Bar To set the air flow 5 switch on the air purge switch to allow air flow Pull the pressure control knob 8 forwards Adjust the gas pressure to the desired value by rotating the knob rotate to direction to increase gas pressure rotate to d...

Page 13: ...e open circuit voltage could be as high as 350V DC at the torch head The torch head encompasses the torch electrode swirl ring for gas distribution in the in the correct manner cutting tip and retaining cap Fitting the P150LT plasma torch On the Jasic Cut 160 plasma machine the below torch fitting instructions will need to be observed Locate plasma torch plug into euro connector socket as shown in...

Page 14: ...stration The basic principle is that the arc is formed between the electrode and the work piece by forcing the plasma gas and the electrical arc through a small orifice within the copper tip This will increase the speed and temperature of the plasma exiting the tip The temperature of the plasma is in excess of 15000 C and the speed can approach that of sound This plasma gas flow in conjunction wit...

Page 15: ...ften the easiest way to cut while minimizing heat input but usually only on cutting currents of 40amps and below Drag cutting does require a drag cutting tip and you need to ensure that the plasma machines output amperage is matched to the amperage with the tip It can often be helpful to use a non conductive straight edge to help maintain a straight cut This technique works best when cutting metal...

Page 16: ...s for bevelling again you need to ensure you utilize the correct plasma machine amperage to match the cutting tips used Ensure that the thickness of the material to be bevelled falls in the amperage range of the plasma machine and cutting tip that you will be using If bevelling by hand a roller and or angle guide can be helpful in maintaining the consistent bevel face and the desired angle which i...

Page 17: ...d cutting systems use of a drag shield cup a standoff guide or a cutting guide will help keep a consistent tip to work distance for best results Kerf width While plasma cutting a void is left behind which is called the kerf in the material being cut Bevel angle In an ideal cut the bevel angle or angle of the cut surface would be perfectly square The plasma cutting process does result in a slight a...

Page 18: ...e output cutting table quality material thickness along with material type being cut as well as the operators skill set Speeds shown below are offered as a guide only for our Jasic cutting systems using compressed air cutting mild steel material with the stated output currents ensuring that the cutting tip fitted matches the stated amperages Material Thickness Amperage Speed mm m Air Pressure 40 5...

Page 19: ...cting the air flow The cutting torch may be burned if the air flow is too low Keep the cutting cable away from sharp edges 8 When the work piece is nearly cut off slow down the cutting speed and release the torch trigger to stop cutting 9 Check the torch consumables frequently to prolong the life 10 Always ensure the correct consumables are fitted in the torch Incorrect items may cause damage to t...

Page 20: ...t rating of 160amps and the supplied plasma torch is the P150LT which has a current rating of 150amps this torch is supplied from new with the 150amp tip fitted When ordering replacement cutting tips please take note that the maximum sized tip to be used would be the 150amp 1 8 cutting tip Using a higher rated tip will give you poor cut performance ...

Page 21: ...21 PLASMA TORCH CONSUMABLE BREAKDOWN The Jasic Cut 160 is supplied with the 6m P150LT plasma torch ...

Page 22: ...22 PLASMA TORCH CONSUMABLE BREAKDOWN The Jasic Cut 160 is supplied with the 6m P150LT plasma torch ...

Page 23: ...23 PLASMA TORCH CONSUMABLE BREAKDOWN The Jasic Cut 160 is supplied with the 6m P150LT plasma torch ...

Page 24: ...24 PLASMA TORCH CONSUMABLE BREAKDOWN The Jasic Cut 160 is supplied with the 6m P150LT plasma torch ...

Page 25: ...ion daily to ensure they have not become loose otherwise arcing may occur when used under load Period Maintenance item Daily examination Check the condition of the machine mains cables welding cables and connections Check for any warnings LEDs and machine operation Check the torch consumable condition and replace if worn Check the compressor air supply and adjust as required Monthly examination Di...

Page 26: ...icult to diagnose cutting issues without understanding the machines use and setup and there are various questions that need to be asked to be able to give the best advice Below is listed a few pointers to help you on your way to obtaining consistently good cut quality Ensure your mains power supply is suited to the plasma cutting machines specifications Ensure the supplied gases or air supply is i...

Page 27: ...e torch along Excessive piloting Keeping the pilot arc maintained will erode the consumables much faster than when cutting keep piloting to a minimum Poor cut quality Improper travel speed Refer to the cutting guide chart on page 18 of this user manual for the correct settings for the material being cut Cutting amperage not correct Refer to the cutting guide chart on page 18 of this user manual fo...

Page 28: ...not dispose of the equipment with normal waste The European Directive 2002 96 EC on Waste Electrical and Electronic Equipment states the electrical equipment that has reached its end of life must be collected separately and returned to an environmentally compatible recycling facility Jasic has a relevant recycling system which is compliant and registered in the UK with the environment agency Our r...

Page 29: ... scope of the warranty Defects due to natural wear and tear Failure to observe the operating and maintenance instructions Connection to an incorrect or faulty mains supply Overloading during use Any modifications that are made to the product without the prior written consent Software errors due incorrect operation Any repairs that are carried out using non approved spare parts Any transport or sto...

Page 30: ...__________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _________...

Page 31: ...__________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _____________________________________ _________...

Page 32: ...www jasic co uk Wilkinson Star Limited Shield Drive Wardley Industrial Estate Worsley Manchester UK M28 2WD 44 0 161 793 8127 April 2020 Issue 3 ...

Reviews: