Page 8
Section 2.
System Description
Figure 1.
Example of Installation
2.1 Product Speci
fi
cations
Maximum Operating Pressure:
50 psi
Output Voltage:
25V DC (max)
Minimum Flow Rate:
152 lpm (40 gpm)
Output Current (adjustable by switch):
5A DC
Maximum Flow Rate:
92 gpm (348 lpm)
Dimensions:
Power Pack (L x W x H):
10 in. x 4.5 in. x 13 in. (25.4 cm x 11.4 cm x 33 cm)
Electrolytic Cell (L x W x H)
:
6.5 in. x 5.5 in. x 12 in. (16.5 cm x 14 cm x 30.5 cm)
Pod (L x W x H):
6.5 in. x 5.5 in. x 6 in. (16.5 cm x 14 cm x 15.3 cm)
Maximum water volume treated:
35,000 gal. (132,000 L)
Chlorine Output:
0.93 lbs. (0.42 kg) per day
Required Salt Level:
4,000 ppm (4.0 gpl)
Input Voltage:
120 V
Weight:
Power Pack:
7 lbs. (3.2 kg)
Electrolytic Cell:
2 lbs. (0.9 kg)
Pod:
1.5 lbs. (0.7 kg)
Input Current @ 120 VAC:
~1.3 A
Input Freq:
47~63 Hz
Heater
Pump
To power outlet
Power Pack
Filter
Pool Intake
Spa Intake
Spa Return
Pool Return
Pod
Cell
The cell and pod must be installed
as the last pieces of equipment in
the circulation plumbing system just
before the pool
Water Flow
Bonding Wire
(to Pump or
Heater)