Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including the
following:
WARNING
EQUIPMENT UNDER PRESSURE:
Always turn pump off prior to installing or servicing the power pack, pod,
or cell. Your pump/
fi
lter system is operated under pressure and the pressure must be released before you begin
work. Please see your pump/
fi
lter owner’s manual for further instructions.
WARNING
To reduce the risk of electric shock,
fi
re or injury, service should only be attempted by a quali
fi
ed pool service professional.
WARNING
Jandy
®
AquaPure
®
Ei
TM
chlorine generating devices are designed for domestic (residential) swimming pool use only.
Contrary use could affect performance, void warranty, and may result in property damage, serious injury, or death.
• Operating a chlorine generator without water
fl
owing through the cell may cause a build up of
fl
ammable gases,
resulting in
fi
re or explosion.
• Keep equipment out of reach of children.
• Do not use if supply cord is damaged.
• A damaged supply cord should only be replaced by the manufacturer, service agent or electrician.
• When installing and using this electrical equipment, always follow basic safety precautions.
• Before performing installation, disconnect all power.
• Connect to a circuit that is protected by a ground fault circuit interrupter (GFCI).
• Do not install within an outer enclosure or beneath the skirt of a hot tub or spa.
WARNING
Installation must be done in accordance with the National Electrical Code (“NEC” or NFPA-70) in the US, and/or any
other local and national installation codes.
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH
. Connect only to a branch circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Contact a quali
fi
ed electrician if you cannot verify that the circuit
is protected by a GFCI. Make sure such a GFCI should be provided by the installer and should be tested on a routine
basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump
without the test button being pushed, a ground current is
fl
owing, indicating the possibility of electrical shock. Do not
use the device. Disconnect the device and have the problem corrected by a quali
fi
ed service representative before
using.
It is required that the water
fl
ow pod is installed in the same piping as the electrolytic cell, without any valves or divert-
ers between them (see Section 3.2, Figure 3).
The
fl
ow pod must be mounted as in Section 3.2, Figure 3.