3.6 Connection to an AquaLink
®
RS Control System or PDA (Optional)
The Jandy
®
AquaLink RS or PDA is a multi-function pool controller which can fully control the function of the Jandy
AquaPure
®
Ei
TM
chlorine generating device. Adjustment of the chlorine production rate can be controlled from the
main menu of the Jandy AquaLink RS or PDA. The AquaLink RS or PDA offers individual pool and spa settings for
output percentage. Refer to the AquaLink RS or PDA Owner’s Manual for more information.
NOTE
The Jandy AquaPure Ei chlorine generating device will communicate with all AquaLink models Rev. K or later.
3.6.1 Verify the Controller Type on the Power Pack is Set Correctly
Before wiring to an AquaLink RS Control System, the controller type must be set to JANDY L/M to allow
communication between the power pack and the AquaLink RS Control System. The default controller type setting on
the power pack is Jandy L/M. Follow the instructions below to verify the controller type is set correctly.
NOTE
The controller type must be set correctly before making the wiring connection between the power pack and
the AquaLink, otherwise the power pack may be locked out of the AquaLink.
WARNING
FOR YOUR SAFETY:
This product must be installed and serviced by a professional pool/spa service technician.
The procedures in this manual must be followed exactly. Failure to follow warning notices and instructions may
result in property damage, serious injury, or death. Improper installation and/or operation will void the warranty.
When using electrical products, basic precautions should always be followed, including the following:
• DANGER: RISK OF ELECTRIC SHOCK WHICH CAN RESULT IN SERIOUS INJURY OR DEATH. Before
attempting installation or service, ensure that all power to the device is disconnected/turned off at the circuit
breaker. Connect only to a circuit protected by a ground-fault circuit-interrupter (GFCI).
• Grounding is required. The unit should be serviced by a quali
fi
ed service representative and should be
properly grounded and bonded.
• Install to permit access for servicing.
• Please read all cautions and safety instructions in the Important Safety Instructions section.
Before
attempting any electrical wiring, be sure to read and follow safety instructions. Wiring should only be
attempted by a quali
fi
ed professional.
Figure 23. Example of Alternative Installation
3.5 Alternative Installation (When Pipe is Obstructed)
If the only suitable length of pipe is obstructed, such as on a multiport valve often found on a sand
fi
lter, it is
acceptable to ‘lean’ the cell over, up to a maximum of 45 degrees (see Figure 23). Mark the feeder holes in the same
angle that the cell will be leaning to ensure that you drill in the right position.
Do not install
past 45 degrees