Use Freeze Protection menu to assign freeze protection to your pool and spa equipment. When a piece of equipment is
assigned to freeze protection, it will turn on when the AquaLink
®
RS detects freezing conditions. The main filter pump
is freeze-protected as a default.
Activation temperature can be adjusted between 34°F and 42°F. Default freeze protection activation temperature is
38º F and will deactivate within 2°F.
Use this menu to adjust the number of hours or mode of Boost Pool.
The system will auto-detect the AquaPure
®
chlorine generator.
Highlight MENU/HELP and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight AquaPure
®
and
press SELECT. Use the UP/DOWN arrow keys to select TIME or MODE. If selecting MODE, use the UP/DOWN
arrow keys to select either SPILLOVER or POOL. If POOL is selected, the return path for the water is to the pool not
the spa.
MENU
HELP
PROGRAM
SET TEMP
SET TIME
SET AQUAPURE
DISPLAY LIGHT
LOCKOUTS
PROGRAM GROUP
SYSTEM SETUP
BOOST POOL
SYSTEM SETUP
ONETOUCH
LABEL AUX
FREEZE PROTECT
AIR TEMP
DEGREES C/F
TEMP CALIBRATE
IN FLOOR CLEAN
MORE
AQUAPURE
BOOST POOL
SETUP
TIME
hrs
24
Use ARROW KEYS
to set value.
Then SELECT.
MODE
POOL
BOOST POOL
SETUP
TIME
hrs
24
Highlight an
item and press
SELECT.
MODE
POOL