22
In the System Set-up Tab, select
“3-Wire” (C)
for the Section Valve Type.
See your Nitrogro Owners Manual for information on the number of
sections and section widths.
In the System Set-up Tab, select
“PWM Close” (F)
for the Control Valve
Type.
Select the PWM Setup Button to enter into the PWM Settings Box. In
the PWM Settings Box, enter a Control Valve Calibration of
1533
, a Coil
Frequency of
122
, a High Limit of
220
and a Low Limit of
50
. The High
and Low Limits can be fine tuned using the Calibrate PWM Limits button
to speed up the response time if necessary.
Enter the Flowmeter Calibration number, approximately 1,340, which is
stamped on the flowmeter on the applicator. Also check and make sure the
units are the same as stamped on the flowmeter, usually Gallon
“10 gal” (H)
.
See your Greenstar Rate Controller Manual for more details.
John Deere Greenstar Rate Controller PWM Setup
Scan to watch
the video