Electric Switches
Momentary push button switch for
raise lower circuit. The height of this
switch should be set so that it gets
pressed when the toolbar lowers in the
rest position when folded. It should
be plugged into the side of the dual
solenoid valve with number 1 and 2
ports (side A). The wire leads coming
from side A should be wired to the
switch in the normally closed position.
Momentary whisker switch for fertilizer
flow on/off. The height of this switch
should be set so that it gets pressed by
the parallel arm at the toolbar height
that you want the fertilizer pump to shut
off. It should be wired in the normally
closed position.
Momentary whisker switch for latch/
folding circuit. The height of this switch
should be set so that it gets pressed
by the parallel arm when the toolbar
is completely raised up. It should be
plugged into the side of the dual
solenoid axle with number 3 and 4 ports
(side B). The wire leads coming from side
B should be wired to the switch in the
normally open position.
1
2
3
4
Dual Solenoid Valve