IS297-22F
J&D Manufacturing • 6200 Hwy 12 • Eau Claire, WI 54701 • 1-800-998-2398 • www.jdmfg.com
Page 12/27
How to use the Stabilizing Chain Harness to Hang Fan:
• On each leg of the Stabilizing Chain Harness measure 1’ from the corner and attach another
quick connect, as shown below.
• These quick connects will be used to attach the hanging chains at the proper location on the
Stabilizing Chain Harness.
18
OSHA requires this fan to
be mounted a minimum of
7’ above the floor.
Must be mounted a
minimum of 2’ below
the ceiling
NOTE: Consideration of the height of frequently used
machinery should be taken into account to
avoid damage and inconvenience.
20
Weight 350lbs
Site Requirements:
• Structure, additional hanging chain, and anchor hardware (not provided) must be
rated for 350lbs
19
1’
3 Louver Mounting Height Recommendations: