TM-6740GE Series
54
Configuring the Camera
Signal Source
Signal Name / Input Pin
Description
Pulse Generator Timer1Out
Pulse Generator 1 output signal.
Pulse Generator Timer2Out
Pulse Generator 2 output signal.
Pulse Generator Timer3Out
Pulse Generator 3 output signal.
Pulse Generator Timer4Out
Pulse Generator 4 output signal.
Note: There is no PLC_ctrl1.
This table show possible signals each input line can accept (“(D)” specifies factory defaults):
Signal Name / Input Pin
I0
I1
I2
I3
I4
I5
I6 I7
External_Trigger_In_Pin6 X(D)
X
X
X
X
X
X X
External_VD_In_Pin7 X
X(D)
X
X
X
X
X X
External_HD_In_Pin9 X
X(D)
X
External_INT_In
X
X(D)
X
X
Internal_FDV_Out X
X
X
X
X X
Internal_LDV_Out
X
X
X
X
X
Internal_CAM_STROBE_Out X
X
X
X
X(D)
X X
PLC_ctrl0 X
X
X
X
X
X
PLC_ctrl2 X
X
X
X
PLC_ctrl3
X
X
X
PLC_Q2 X
X
X
X
PLC_Q3
X
X
X
X
PLC_Q6 X
X
X
X
PLC_Q7
X X X X
Counter1Gt
X
X
X
Counter1Eq
X
X
X
Timer1Out X
X
X
X(D)
Timer2Out X
X
X
X(D)
Timer3Out
X
X
X(D)
X
Timer4Out
X
X
X
5.8.2
ControlBits
There are 3 Control Bits: PLC_ctrl0, PLC_ctrl2, and PLC_ctrl3. Note that PLC_ctrl1 is not available. The control
bits can be used as software triggers by toggling between two states: True and False. True sets the signal High,
while False sets the signal to Low.
When a bit is toggled on the host software, a Write Register command is sent to the camera. The arrival time
of the packet depends on current network traffic therefore is varied. These are recommended for testing
purposes. For more precise trigger usage please use an external input trigger signal thru the 12-Pin connector.
For a constant periodic trigger signal please use the Pulse Generators (Timers).
Summary of Contents for TM-6740GE
Page 2: ......
Page 15: ...Installation 15 TM 6740GE Series Figure 4 Back Focus Set Screw Locations...
Page 26: ...TM 6740GE Series 26 Operation 3 8 Camera Timing Charts...
Page 27: ...Operation 27 TM 6740GE Series...
Page 28: ...TM 6740GE Series 28 Operation...
Page 34: ......
Page 70: ...TM 6740GE Series 70 Appendix...
Page 71: ......