Configuring the Camera
Figure 16.
Image Output Example
ScanMode:
controls the image size captured by the image sensor. By changing to a smaller size you can achieve
a faster frame rate. After changing ScanMode it is necessary to adjust the Width and Height value to a valid
value. Available options (expressed in unit of Width x Height pixels):
−
A_640x480
−
B_640x160
−
C_224x480
−
D_224x160
BinningMode:
the 6740’s Binning Mode can group the image sensor pixels together to make a larger pixel. The
larger pixel will have all the light from the 4 original pixels. This mode can be used for application in low light
level. Since the pixels are grouped, the image size is also affected. Available options are:
−
Binning1x1: results in image size of 640x480.
−
Binning1x2: results in image size of 640x240.
−
Binning1x4: results in image size of 640x120.
−
Binning2x1: results in image size of 320x480.
−
Binning2x2: results in image size of 320x240.
−
Binning2x4: results in image size of 320x120.
−
Binning4x1: results in image size of 160x480.
−
Binning4x2: results in image size of 160x240.
−
Binning4x4: results in image size of 160x120.
TestImageSelector:
shows a software generated test pattern. Use this feature for debugging purposes.
Available options are:
−
Off: turn off test pattern generator and resume normal operation.
−
DeviceSpecific: shows diagonal lines on black background. Generated by the camera’s
CPU.
−
IPEngineTestPattern: shows horizontal striped gradients running right to left.
Summary of Contents for TM-6740GE
Page 2: ......
Page 15: ...Installation 15 TM 6740GE Series Figure 4 Back Focus Set Screw Locations...
Page 26: ...TM 6740GE Series 26 Operation 3 8 Camera Timing Charts...
Page 27: ...Operation 27 TM 6740GE Series...
Page 28: ...TM 6740GE Series 28 Operation...
Page 34: ......
Page 70: ...TM 6740GE Series 70 Appendix...
Page 71: ......